- 40 -
User
NO
User access
NO
Fire
NO
Reset Fire
NO
Timer
NO
Autotest
NO
ON Arming
NO
HOME Arming
NO
AREA Arming
NO
PERI Arming
NO
Disarmed
NO
Normally active
NO
Blinking
NO
OC audio en.
NO
O.C. label
Tamper:
it activates with the tamper of at least one of the associated zones
Antimask:
it activates with the antimasking of at least one of the associated zones
Mains power failure:
with “YES”, it activates when the control panel or the supervised power units connected in series
are not powered, after a delay programmable in minutes. (see “Times”)
Power unit failure:
with “YES”, it activates when the voltage supplied by the power unit of the control panel or by that of
the supervised power units connected in series is higher than 16 V = or when it is lower than the voltage generated by the
battery or when the output voltage on the various board positives is lower than 10 V =
Low battery:
with “YES”, it activates when the battery of the control panel or of one of the supervised power units connected
in series drops below 10.5 V and there is no charging voltage. It resets when voltage rises above 12.8 V =
No battery:
with “YES”, it activates when the battery of the control panel or of one of the supervised power units connected
in series, drops below 3 V =
Battery faulty:
with “YES”, it activates when the battery of the control panel or of one of the supervised power units
connected in series, drops below 9.5 V=
No telephone line:
with “YES”, it activates when the presence of the telephone line is no longer detected
Call in progress:
with “YES”, it activates when a telephone communication is in progress,
OC on Ring:
by setting “YES”, it activates when the control panel receives a GSM call from a phone number enabled to
perform the function.
User:
it activates from RTC, from Keypad entering a user code with “User OC Enab.” enabled, from Timer or from RING.
User Access:
by setting “YES”, it activates when the associated User Code is entered (see User Profiles)
Fire:
it activates when there is a FIRE alarm coming from one of the satellites.
Reset Fire:
Activated when an enabled user performs a “Reset Fire Line” operation (pressing key 2 in the “User Menu”).
If the time is set as Bistable, the output is activated for 15 seconds.
Timer:
it activates when the Timer reaches the pre-fixed day and time; it cannot be controlled by the user.
Autotest:
Activated when the central control unit performs the “Autotest” function.
If the time is set as Bistable, the output is activated for 3 seconds.
ON Arming:
by setting “YES”, it activates when the partition is armed in ON
AccenYESone HOME:
by setting “YES”, it activates when the partition is armed in HOME
AccenYESone AREA:
by setting “YES”, it activates when the partition is armed in AREA
AccenYESone PERI:
by setting “YES”, it activates when the partition is armed in PERIMETER
Disarmed:
by setting “YES”, it is activated when it is DISARMED, or when the PATROL TOUR TIME ELAPSES. (using the patrol
tour function; this signals that the patrol code is not entered within the programmed “patrol tour time” partition reactivation time)
Normally active:
set to NO the output supplies a transistorized negative when activated. Set to YES, the output usually
supplies a transistorized negative which is lost when activated.
Blinking:
by setting “YES”, it flashes for the time it is active
Audio OC. state (communicates the state of the Open Collector output):
By setting “YES” the variation of the state of
the O.C. output is vocally communicated.
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
O.C. label:
it is possible to associate a description of 16 alphanumerical digits for every open collector;
Press
(CLR)
to vary
Writing keys::
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(ENT)
to confirm
Press
(ESC)
to go back
Open Collector
Low battery
NO
Batt. Unconnected
NO
Battery fail
NO
Tel. line fault
NO
Dialler on-line
NO
OC on Ring
NO
Tamper
NO
AntiMask
NO
Mains Fault
NO
Pwr supply fail
NO
to following
page
from previus
page