- 32 -
Test EN solo dgt
NO
Conform.EN50131
NO
Ctr. panel label
Installation
from previus
page
Conditional arm
YES
PSTN enable
NO
XGSM
NO
PSTN enable
: By setting “YES”, the PSTN integrated dialler is enabled to dial the programmed calls.
XGSM
: By setting “YES”, the GSM integrated dialler is enabled to dial the programmed calls.
XGSM485
: By setting “YES”, the GMS dialler with serial connection for making the programmed calls is enabled.
Conditional arm:
By setting NO, the control panel is armed anyway, even if there are unbalanced lines or tamper signals.
By setting YES, the control panel analyses the state of the zones, when an arming command is given; even if there
is only one u nbalanced immediate zone, the control panel is not armed.
Example:
if wanting to avoid sending useless signals, for a manoeuvre error, the setting must be
YES
.
NOTA:
Impostando
NO
decade la conformità alle
Norme EN50131.
Code Reset to Default:
By setting “NO”, the “Reset Codes” procedure returns just the Installer Code to its factory
setting. By setting “YES”, the “Reset Codes” procedure returns all programming to the default settings.
EN50131 conformity
: By setting “NO” or if certain parameters are edited (see the “EN50131 - Grade 2 Conformity”
section) the unit no longer complies with EN50131 standards.
Test EN of Digital numbers only
: By setting “NO”, the test of the phone numbers set by EN50131 comprises all the
programmed phone numbers. By setting “YES”, the test of the phone numbers only comprises the phone numbers
programmed with digital protocol.
System events count:
It is the number above which repetitive Tamper or Fault events relating to the central control
unit and the various peripherals connected (Satellites, Buzzers, etc. excluding zone inputs) no longer cause the
programmed outputs to enter alarm mode, but are instead listed and saved in the event memory; by setting the
value 0 (zero) as the code number, the function is eliminated and none of the events are coded.
WARNING:
this function is re-enabled with the first change of status (ON/OFF) of the Partition with which the
peripheral is associated.
NOTA:
Impostando 0, 1 o 2 decade la conformità alle Norme EN50131.
Country:
Adjusts the control panel to the local behaviours/electric standards.
NOTE:
setting the nation as “BELGIUM” automatically guarantees compliance with T014 with regard to resetting
the TAMPER Alarm
Control Panel Label:
16 alphanumerical string, indicated when access to the programming menu
Press
(CLR)
to vary
To access other entries press
(
)
or
(
)
Write the number to be set
Press
(ENT)
to confirm
Partitions
Partitions
ENT
Partition
: Select which partition we are programming from 1 to 8.
Zone
: By setting YES, the zone is associated to the partition; the zones can be associated with more than one
partition; in this case they will be common to the partitions they are associated with.
By default, all zones are associated to partition 1. In this way, the system can immediately manage a single system.
Exit time:
Exit time of the timed zone and 24H timed associated to the partition
Entry time:
Entry time of the timed zones and 24H timed associated to the partition
Buzzer announce:
it is possible to ensure that the automatic armings are pre-warned by a beep, on the enabled
keypads, for a time programmed under “warning duration”. During this period of time, by entering an enabled code,
it will be possible to delay arming by one hour (extraordinary inclusion).
Ex
. If 5 minutes are programmed, it starts to sound 5 minutes before arming.
NOTE
: in the event of use of the timing programming, to prevent the voiding of compliance with EN50131, a warning
time must be programmed.
Patrol tour time
: is programmed in minutes, once timer is expired, the patrol partition is re-armed at
ON
. Essentially,
the function means that any user code with a patrol tour attribute associated with this partition turns off the partition for
the period of the programmed patrol timer. When the patrol tour timer elapses, the partition reverts to its initial work
mode. In case of reset or watchdog, the patrol partitions automatically activate.
Double check:
in seconds; in the case of a user code configured with “Double consent” or with TOY, this defines
the period for recognition with the keypad of a second user code or coupled TOY configured with “Double consent”.
Partition label:
it is possible to associate a description of 16 alphanumerical digits for every partition
Press
(CLR)
to vary
Writing keys::
(1)
abc1
(2)
def2
(3)
ghi3
(4)
jkl4
(5)
mno5
(6)
pqr6
(7)
stu7
(8)
vwx8
(9)
yz.
(0)
_’0
Press arrows
(
)
and
(
)
to position the cursor
Press
(ENT)
to confirm
Zones 1
YYYYYYYYYYYYYYYY
Patrol tour time
0 (0.. 255)
Code R. to deflt
NO
Exit time
MM:SS 1: 0
Entry time
MM:SS 0: 30
Buzzer announce
0 (0.. 60)
Double check
0 (0.. 255)
Partition label
Partition #
1 (1 ... 8)
XGSM485
NO
Sys. events count
10 (0 ..10)
Country
Italy
to following
page