- 13 -
Inertial Vibration and Inertial Roller Shutter Zones
NC Inertial Vibration and NC Inertial Roller Shutter Zones
Installation
• In order to guarantee the correct system installation, it is important to lock the cables of the different equipment with the strips using the ap-
propriate turrets of the housing .
• To guarantee electrical safety, the wires must be fastened with a clip directly on the protective sheath
• The 3 wires for the 230 V ~ mains power supply and the 2 wires for the power supply must be securely fastened together using a proper clip
(as shown in the figure) to prevent them coming into contact with sensitive parts of the central control unit if they should come loose from the
terminal block.
These configurations permit direct management of Inertial or Roller Shutter sensors with one 4700
ohm R1 terminal resistor for the
XSAT36 and XSATPW
inputs and one 2200 ohm R2 terminal resi-
stor (not supplied, or two 4700 ohm R1 resistors in parallel) for the Capture central control unit, C8.
To adjust the sensitivity, the “Number of Pulses” step inside the programming of the single zone is
used (1= HIGH sensitivity / 120= LOW sensitivity). The equipment is protected using the dedicated
TAMPER
line or an input zone other than the central control unit, programmed in
TAMPER
mode.
N.B.:
this type of connection cannot be used in the zones in the A500 and A500 Plus keyboards
and the XSAT HP expansions.
R2
2.200 ohm
1) Red
Value: 2
2) Red
Value: 2
3) Red
Number of zeros 2
4) Gold
Tolerance: 5%
Balancing resistance
The colours of R1 and R2
terminal resistance are:
R2
L2
L1
L3
L4 L5
L6 L7
L8 T
R2
In those zones programmed as Inertial Roller Shutter, the central control unit does not signal the open zone if the connection cable is interrupted.
In those zones programmed as Inertial Vibration, the central control unit signals the open zone if the connection cable is interrupted.
L2
L1
L3
L4 L5
L6 L7
L8 T
These configurations permit direct management of Inertial or Rolling Shutter sensors
with negative reference.
To adjust the sensitivity, the “Number of Pulses” step inside the programming of the
single zone is used (1= HIGH sensitivity / 120= LOW sensitivity).
The equipment is protected using the dedicated
TAMPER
line or an input zone other
than the central control unit, programmed in
TAMPER
mode.
N.B.:
this type of connection cannot be used in the zones in the A500 and A500 Plus
keyboards and the XSAT 36, XSAT PW and XSAT HP expansions.
In those zones programmed as Inertial Roller Shutter, the central control unit does not signal the open zone if the connection cable is interrupted.
In those zones programmed as Inertial Vibration, the central control unit signals the open zone if the connection cable is interrupted.
Anti-tamper KIT installation (Optional)
1. Perforate the wall in correspondence with the hole at the bottom of the housing destined for the anti-tamper.
2. Insert the wedge in the hole in the wall and tighten the spacer.
3. From the outside, insert the anti-tamper on the appropriate hole at the bottom of the housing.
4. Tightly fix the housing on the wall, checking that the spacer screwed on to the wedge, presses against the antitamper
button spring.
5.
Connect the cable of the strain relief KIT to the SNATCH JUMPER on the central control unit board.
HOLES
FOR WALL
MOUNTING
HOLE FOR
STRAIN
BATTERY
RETAINER
SIGNAL CABLES
INLET HOLE
220V POWER SUPPLY
INLET HOLE
FOR 230V POWER
CORD FASTENING
WITH CLIP
FOR GSM ANTENNA
CABLE FASTENING
WITH CLIP
FOR WI FI ANTENNA
CABLE FASTENING
WITH CLIP
FASTON FASTENING
YELLOW/GREEN CABLE
FOR EARTHING THE
COVER
FOR TELEPHONE
CABLE FASTENING
WITH CLIP
FOR FASTENING
THE SIGNAL
R1
4.700 ohm
1) Yellow
Value: 4
2) Purple
Value: 7
3) Red
Number of zeros 2
4) Gold
Tolerance: 5%