- 39 -
Open Collector
O.C. Prog.
ENT
PhiSical O.C.
CPN T.OC 1
The Open Collectors are Optional Outputs that enable extending the system potentials. The integrity of the system
and the good functioning of these outputs is guaranteed only by using the Optional Module “MR4 / MR8”.
The terminals L1, L2, L3 and L4 of the central control unit and all the LXX terminals of the satellites (
NO XSAT36/XSATPW/
XSATHP
) can be programmed either as a zone input or as an Open Collector output with negative reference; or as both at
the same time (the line input is controlled directly by activation of the relative O.C.).
WARNING:
It is not possible to use the terminal as an OC output if programmed and physically cabled to control
an external sensor and, similarly, it is not possible to use the terminal as a zone input if programmed and physically
connected to control a load with the OC output.
The central control unit also has 3 Open Collector outputs, OC1, OC2 and OC3, that correspond in the programming
to the terminals M.OC 1, M.OC 2 and M.OC 3 respectively.
O.C. #:
Select the number of the O.C. to be programmed.
Phisical O.C.:
Select the physical terminal of the central control unit or satellite to be associated with the O.C. output.
O.C. Activate time:
Inactive:
the output does not activate
;
Bistable:
the output follows the state of the associated function
MM:SS:
the output will activate for the set time (MM = Minutes / SS = Seconds)
HH:MM:
the output will activate for the set time (HH = Hours / MM = Minutes)
GG:HH:
the output will activate for the set time (GG = Days / HH = Hours)
“Times” Note:
the set values may be automatically rounded off after confirmation with
(ENT)
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Enter the chosen number
Press
(ENT)
to confirm
Press
(
)
or
(
)
to move
Partitions:
Select one or more Partitions to be associated to the O.C. These are automatically associated with all
the zones belonging to the Partitions set at YES. For the events of a single zone or a set of targeted zones, it is
necessary to leave everything at NO and to associate the O.C. with the single zones of reference.
Alarm:
it activates with at least one of the associated zones in alarm state
Re-balancing:
it activates with the balancing of all the associated zones
Exclusion:
it activates with the exclusion of at least one of the associated zones
Unbalancing:
it activates with the unbalancing of at least one of the associated zones
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
Press
(ESC)
to go back
Antimask
ENT
Antimask
Activation CP Relay:
the alarm caused by the anti-mask signalling if set on YES will cause the activation of the
control panel relay for the time programmed
Activation Relay:
the alarm caused by the anti-mask signalling if set on YES will cause the activation of the extension
relay (C-NC-NA) for the time programmed.
Sirens Activates:
The alarm caused by the anti-mask signalling if set at YES will cause the activation of the Buzzer
with serial connection for the time programmed.
Memo Alarm:
the alarm caused by the anti-masking signalling can be recorded in the events memory of the control
panel; a YES enables the function, with NO the event will not be recorded
Memo Restore:
the restore of the anti-masking signalling can be recorded in the events memory of the control
panel; a YES enables the function, with NO the event will not be recorded
Buzzer Activation:
the alarm caused by the anti-mask signalling if set on YES will cause the keypad buzzer to sound
The sound time can be programmed in the menu, time programming
24 H anti-mask:
setting this step on YES, the anti-mask will activate the signalling also at disarmed system.
Press
(CLR)
to vary
Press
(ENT)
to confirm
Memo alarm
NO
Activ. CP relay
YES
Attiva buzzer
YES
Antimask 24
NO
Relay on sat.
nnnnnnnn
Memo riprist.
NO
Partitions
YYYYYYYY
O.C. #
1 (1 ... 32)
Alarm
NO
Rebalancing
NO
Bypass
NO
Unbalancing
NO
Sirens activ.
nnnnnnnn
O.C. activ. time
Inactive
to following
page
from previus
page