Ynnnnnnn
Enter Installer Code followed by (ENT)
(by default:
Installer Code 1 = 000000; Installer Code 2 = Disabled
)
If the code is recognised, the wording “
Capture 32/16/8
” will appear
Press
(ENT)
to enter
PROGRAMMING
Keypads:
By setting “YES”, the individual keypad connected on serial is enabled
Satellite:
By setting “YES”, the individual satellite connected on serial is enabled
Sirene (seriali):
By setting “YES”, the individual siren connected on serial is enabled
Note
: It is possible to install the various accessories not in sequential order; it is therefore possible to enable the
serial 7 accessory even without having installed the previous ones.
Satellite type:
The type of satellite model connected is defined;
Satellite address xx:
indicates which satellite we are programming from 1 to 8.
This step is used to define which types of satellites have been connected to the serials; with this pogramming a
series of controls are activated, used to avoid performing programming errors during association of the software
zones to the physical ones.:
- XSAT36/XSATPW/S.POW:
The XSAT36 is a wired satellite with a maximum of 36 zones. The XSATPOWER has
the same characteristics as the XSAT36 with the addition of management of its power supply unit. The XPOWER
is a satellite for sole management of its power supply unit.
- XSATWS:
it is possible to acquire up to 32 radio detectors
- XGSM485:
wired satellite with maximum 3 single or double balancing inputs and/or 3 O.C. outputs.
- XSATHP:
wired zone extension peripheral that adds up to 3 normal EOL inputs and up to 32 wired addressable detectors.
- Virtual XSATHP:
software function that simulates an XSATHP and allows connecting up to 32 addressable
detectors directly to the serial buses of the control panel.
WARNING!!!
Only one single Virtual XSATHP is supported in the configuration of the panel
.
WARNING!!!
The Virtual XSATHP function CANNOT BE USED if using physical XSATHP devices connected to the panel.
Pairing XSAT WS:
This menu is used to establish which radio satellites must work in pairs.
The first value corresponds to satellites 1 and 2, the second to satellites 3 and 4, the third to satellites 5 and 6, the
fourth to satellites 7 and 8
To access other entries press
(
)
or
(
)
List sat.->BIP:
This menu is used to define a sequential order between the various radio satellites.
Position X:
This sequential order defines that the remote controls acquired on the first satellite will be from number
1 > 64, those acquired on the second satellite will be from 65 > 128, those acquired on the third satellite will be
from 129 > 192 and so on.
Satellite address:
indicates the address of the satellite saved in this position.
Virtual XSATHP:
This menu allows you to define what are the sensors connected and managed directly by the
serial port of the system. Detectors connected to the serial port must be numerated from 1 to 16.
Sensors:
Setting “YES”, enables the single sensor with serial connection (HP series).
EWEB/EWEB WIFI:
Setting “YES”, enables the EWEB / EWEB WIFI board
Press
(CLR)
to vary
Press arrows
(
)
and
(
)
to position the cursor
To access other entries press
(
)
or
(
)
Write the number to be set
Press
(ENT)
to confirm
Installation
Installation
ENT
to following
page
Satell.
nnnnnnnn
15 DIC 06
00 : 00 : 15
Capture ...
avs electronics
00 : 00 : 15
Satellite type
ENT
List sat.->BIP
ENT
Satell. add. 1
XSAT36/PW/S.POW
Position #
1 (1..8)
Satell. addr.
0 (0..8)
XSATWS 1 with 2
NO
Pairing XSATWS
ENT
Sirens
nnnnnnnn
Virtual XSATHP
ENT
Sensors
nnnnnnnnnnnnnnnn
EWEB / EWEB WIFI
NO
SOME PROGRAMMING VALUES MIGHT NOT CORRESPOND TO THOSE ON THE KEYBOARD BECAUSE THEY