- 44 -
User profile:
Every User Code can be associated to one of the 32 available profiles.
The user profiles identify 32 different personalisations to which every user code can refer. The personalisations
consist in the enabling or not of certain keypad functions. The keys that refer to the functions are shown in brackets.
Example:
By enabling the “Arms at ON” function, the key (ON) is consequently enabled. If a user code is associated
to this profile, the user will have the possibility of arming at ON
.
Memory view - command (MEM):
“YES” enables the Code to the possibility of examining the events memory of
the control panel.
OFF ZONE func. - command (ZONES):
“YES” enables the Code to the possibility of excluding the zones from
keypad or from RTC with command (0).
Buzzer exclusion:
“YES” enables the Code to the possibility of excluding the sound of the buzzer of the keypad.
Enables User OC:
“YES” enables the Code to activate the OC outputs from keypad or from RTC using command (6).
Enables RTC fun- (Enables RTC functions) (Remote Telephone Control):
“YES” enables the Code to remotely
manage the Control Panel through the PSTN or GSM line.
Stop dialler (interrupts telephone communication):
“YES” interrupts the current telephone communications and
those awaiting recognition of the user code (keypad, TOUCH or BIP) and, during a telephone call, pressing key 3
on the phone being called if the user code is associated.
Code change - command (1):
“YES” enables the Code to the possibility of varying itself.
Change tel. par. (Changes telephone parameters) - command (1):
“YES” enables the Code to the possibility of
varying/checking the telephone parameters:
- Phone numbers with VOCAL or SMS protocol and with user Partitions consistent with those of the phone number
- Check residue credit SIM Card
- Check field intensity GSM
- Variation SIM Card Expiry Date if the code is Master
Immediate disarm:
“YES” enables the Code for the disarming of the control panel, without pressing key (5) from
the keypad (it must, however, be enabled to disarm, see
Disarms control panel
).
Disarms Timer - arm (disarms with timer active):
“YES” enables the Code to the disarming of the control panel,
even if the control panel has been previously armed by the timer. “NO”, the Code does not have the possibility of
disarming the control panel, until the automatic disarming of the timer.
PO inhibition - command 1:
By setting “YES” it enables the Code to block the Timer
Activates overtime - command (8):
“YES” enables the Code to postpone the arming by one hour, from Timer, for
a maximum of three times (see Timer).
Date/Time - command (1):
“YES” enables the Code to the possibility of varying the date and time
Zones walk Test:
The zones’ walk test function allows to display the state of all zones for the control panel/keypads/
satellites.
- Key
(5)
, allows to deactivate or activate the memory function. Also, by exiting and entering the MEMO function,
the previous memorisations are deleted.
- Key
(CLR)
, allows exiting from the Zones’ Test function.
- The arrow keys
(
)
and
(
)
allow selecting the group of zones to be displayed.
- The wording
(MEMO)
signals that the memorisation modality is active, therefore the unbalancing of one or more
zones, causes the relative memorisation.
Note:
for the lines on the keypads the MEMO function is always active and cannot be excluded
Test Outputs:
“YES” enables the User Code to carry out a function check of the outputs of the control panel
consisting in their activation for 3 seconds (User Manual).
Enable Installer:
Enable the Installer for access to programming through the keyboard, direct connection through
USB port or remote phone connection.
Reset fire loop - command (2):
“YES” enables the Code to perform the FIRE Alarm Reset (User Manual).
Press
(CLR)
to vary
Press
(
)
or
(
)
to move
Press
(ENT)
to confirm
Press
(ESC)
to go back
User profiles
ENT
Immediate disarm
YES
Disarm timer-arm
NO
Activat. overtime
NO
User prof. #
1 (1 .. 8)
User Profiles
Code change
YES
Change tel. par.
YES
Memory view
YES
OFF ZONE func.
YES
Enable RTC func.
YES
Stop dialler
YES
Buzzer exclusion
YES
Date / Time
YES
Enable User OC
YES
Enable Install.
YES
Timer bypass
NO
Zone Walk Test
NO
Test outputs
NO
Reset fire loop
NO
to following