- 69 -
End of programming and return to
“Installation”
menu
EPROM version
ENT
EPROM version
V x.xx
Eprom version
The software of the control panel is displayed in this menu.
The software version of the keypad is displayed by simultaneously pressing keys
(CLR)
and
(ESC)
.
Reset the Codes - Sectors disconnection
In case of losing the Installer Code, programming of the control panel would be impossible as would the possibility of varying it.
It is possible to Reset the installer code by activating a particular procedure.
• Close the
SERVICE jumper
on the board of central control unit and keep it closed.
•
Turn the board of the central control unit off and then on again.
•
the alarm relay activates after a few seconds; as soon as it does, remove the
SERVICE jumper
on the board of central control unit
.
•
The alarm relay automatically de-excites after approximately 2 seconds.
•
The control panel now disarms the previous armings, and immediately enters the installer menu on the keyboard with address 1, from which
the eventual amendments to programming can be carried out
•
The Installer code is reset to default value (
000000
)
ATTENTION: By setting programming step “R. Def Prg. Codes” to “YES”, the Code Reset sets all programming to default values.
Menu standby
ENT
Rem. time: (min.)
60
Menù standby
By accessing this modality, there will be the possibility of blocking all alarm signals for 60 minutes, in order to
comfortably intervene in the installation or maintenance of the system.
The time can be reset at 60 minutes by simply exiting and accessing this menu again or by pressing any key.
Zones Walk Test
The zones’ test function allows to display the state of all zones for the control panel/keypads/satellites.
- Key
(5)
, allows to deactivate or activate the memory function. Also, by exiting and entering the MEMO function,
the previous memorisations are deleted.
- Key (CLR), allows exiting from the Zones’ Test function.
- The arrow keys (
) and (
) allows exiting from the Zones’ Test function.
- The wording
(MEMO)
signals that the memorisation modality is active, therefore the unbalancing of one or more
zones, causes the relative memorisation.
Note:
for the lines on the keypads the MEMO function is always active and cannot be excluded
Zones Walk Test
ENT
I.BA 1
YYYYYYYY
KBD 1 MEMO
nn
I.BA 1
nnnnnnnnnn
I.EX 1
nnnnnnnnnn
Ctr panel
ENT
Keypad number
1 (1 .. 8)
from previus
page
Satell. add.
1 (1 .. 8)