Start error stop
AP 5.4
AP 5.6
Function for operation with product sensor.
Determines the reaction of the machine on a product start error. A product
start error occurs in the following cases:
y
If a further start signal arrives, before the current label is completely printed.
y
With mounted I/O board only
: If a reprint is requested, before the first label
after powering on is printed.
y
If a start signal arrives and no printjob is loaded.
If a product start error occurs, the machine stops and displays the appropriate
status message. If an I/O board is installed, the following output signals are
activated (set low):
y
ERROR\
y
MACHINE STATUS\
On
Start errors are worked up (the machine stops!) (default setting)
Off
Start errors are being ignored.
Product length
AP 5.4
AP 5.6
Function for operation with product sensor.
If this function is activated, the printer ignores all start signals until the product
has passed the dispensing edge.
0.0 mm
Setting range: [0.0…1999.9] mm; Default setting.: 0,0
Current mode
AP 5.4
AP 5.6
¯
Only in production mode.
¯
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
The setting of this parameter influences the impact of the paramters
Min rew.
current
and
Max rew. current
.
Table values
Display of the automatically calculated motor current chart PWM values
(in %). On the base of this setting, the printer calculates the motor current val-
ues for
Min rew. current
and
Max rew. current
out of print speed and material
width. The calculated values appear as default 100%.
Absolute values
With this setting, the printer doesn´t calculate and doesn´t adapt to material
width and print speed. The set values for
Min rew. current
and
Max rew.
current
are given to the output stage without a modification. The valueas ap-
pear as absolute values.
¯
The setting "Absolute values" should only be applied by qualified