Cut speed
AP 5.4
AP 5.6
¯
Only with mounted and activated cutter (
SYSTEM PARAMETERS >
Periph. device
= „Cutter“).
The cut speed is to be adjusted to the material thickness and strength.
x inch/s
Setting range: 2 to 5 inch/s; Unit interval: 1 inch/s
y
2 inch/s: extremely slow; for thick and strong material
y
5 inch/s: extremely fast; for thin material
Cut position
AP 5.4
AP 5.6
¯
Only with mounted and activated cutter (
SYSTEM PARAMETERS >
Periph. device
= „Cutter“).
The cut position is identical to the detected gap position, i. e. with the start of
the label. Fine settings to meet specific customer requirements can be pro-
grammed using the parameter
PRINT PARAMETER > Cut position
.
x inch/s
Setting range: -2.0 to +2.0 mm; Unit interval: 0.1mm
y
Maximum offset in feed direction: -2.0 mm
y
No offset: 0 mm
y
Minimum offset against feed direction: -2.0 mm
Double cut
AP 5.4
AP 5.6
¯
Only with mounted and activated cutter (
SYSTEM PARAMETERS >
Periph. device
= „Cutter“).
Joining grids or the gap area between the labels can be removed using a
double cut, thereby improving the outline.
The first cut is offset by the distance set from the recognized gap position
away in the feed direction, the second cut is made at the gap position.
A possible correction of the cut position ("Cut position" function) is calculat-
ed for both cuts and must be taken into consideration.
x inch/s
Setting range: 0.0 to 5.0 mm; Unit interval: 0.1mm
Normal simple cut: 0.0 mm
¯
The smallest possible double cut distance of 1.0 mm must be adhered to!