03/10 Rev. 5.05-00
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
68
y
Printhead pressure lever was opened during the printing of a label.
y
Start print error
y
Other errors, which keep the printer from printing
¯
During the initialization (powering up) of the printer, the ERROR-signal is
instable!
Prin Offl
In addition to the above mentioned cases avtivate the following events the
ERROR-signal:
y
The printer is in offline mode
y
The printhead pressure lever is open
y
„I/O board pause“ mode
y
Stopped mode (the printing was stopped)
Error Polarity
AP 5.4
AP 5.6
¯
Only with an I/O board mounted.
Switches the polarity of the ERROR signal.
Level high activ
The output is high when it is active, otherwise low.
Level low active
The output is low when it is active, otherwise high. (Default)
Status output
AP 5.4
AP 5.6
¯
Only with an I/O board mounted.
This parameter defines different events, which activate the output signal
MACHINE STATUS.
Low ribbon warn
The signal is activated, if the ribbon roll diameter is less than the limit.
P
See parameter
Foil end warning
on page 68.
Print job ready
The signal is activated, if the printer has finished image processing and is
ready to start printing.
The signal is
not activated
, if:
y
the print job is done,
y
the print job was stopped,
y
the printer was switched to offline mode,
y
the printer is in pause mode.
Status polarity
AP 5.4
AP 5.6
¯
Only with an I/O board mounted.
Switches the polarity of the MACHINE STATUS signal.
Level high active
The output is high when it is active, otherwise low.
Level low active