03/10 Rev. 5.05-00
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
77
The diameter up to which the Pullback current is throttled down to zero
(parameter
Back diameter
), and the diameter, from which on the brake cur-
rent starts (parameter
Brake diameter
).
The parameter
Pullback current
sets the support current for the rewinder at
the minimum diameter of 25 mm. When the diameter of the rewound label
web reaches the set value (Back diameter), the support current will be throt-
tled down to a mimimum.
Back diameter
AP 5.4
AP 5.6
Pullback current diameter
P
See parameter
Pullback current
on page 118.
¯
If the label web is
loose
, while it is fed back under the printhead,
decrease
this value in small steps. If the material is
tightened
too much,
increase
the
value in small steps.
XX mm
Setting range: 0-120 mm; Default setting: 50 mm
Brake current
AP 5.4
AP 5.6
¯
Only in production mode.
¯
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Sets the brake current
P
See parameter
Pullback current
on page 118.
XXX
Setting range: 0-100; Default setting: 0
Brake diameter
AP 5.4
AP 5.6
¯
Only in production mode.
¯
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Sets the break diameter.
P
See parameter
Pullback current
on page 118.
XXX
Setting range: 0-120; Default setting: 120