Installation & Operation Manual
840
Document # LTRT-92224
Mediant 8000
Problem
Possible Cause(s)
Actions to Take
See:
ES board is
Disabled (colored
red
in the EMS) and
all it's LEDs are
turned off.
The uplink of the
Ethernet Switch
board is
disconnected.
Connect the uplink to the ES board.
If the ES board doesn't become
Enabled (colored
green
in the EMS)
– reset it by performing
Lock/Unlock
actions.
'Working with the
ES boards' on
page
Problems with Media Gateway boards
Media Gateway
board is Disabled
(colored
red
in the
EMS)
Media Gateway
board is completing
the Unlock action
It may take up to 3 minutes for the
Media Gateway board to complete
the reboot that accompanies the
Unlock action. Wait patiently.
'Working with the
Media Gateway
Boards' on page
Duplicate IP address Verify that no other equipment uses
the same IP addresses as the ones
configured for the Media Gateway
board.
If the "duplicate IP address"
problem exists do one of the
following:
locate and reconfigure/remove the
faulty external equipment
update Media Gateway board's
configuration (redefine IP
addresses)
'Working with the
Media Gateway
Boards' on page
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...