33. Configuring Security Settings
To apply the new X.509 configuration to Media Gateway boards:
1.
In the Security Settings screen, click the Maintenance Actions icon
in the
top-right corner and select the
Download Certificates to VoP Boards
option;
the Generate X.509 Files dialog is displayed.
•
Select one of the following options:
♦
All Boards
- apply new X.509 configuration to all Media Gateway
boards
♦
Select Board
- apply new X.509 configuration to the specific Media
Gateway board; if you select this option, choose the specific board from
the drop-down list.
Figure
33-3: Activating X.509 Certificates
2.
Click
OK.
The new X.509 configuration (currently configured in the Media Gateway Security
Settings tab) is applied to the specified board(s). The
VoP Boards Synchronized
With Media Gateway Configuration
and
VoP Boards Not Synchronized With
Media Gateway Configuration
lists are updated accordingly.
Note:
The new X.509 configuration is applied to the Media Gateway board instantly
without any effect on the board’s service.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...