Version 6.6
479
October 2014
Installation & Operation Manual
38. Configuring the PSTN Subsystem
Table
38-8: SS7 Data Link Properties - Data Link MTP Tab
Parameter Name
Type
Provisioning
Type
Description
Trunk ID
Integer
0-84
Online
Relevant for Layer2Type=MTP2 only.
Defines the ID of the trunk used for carrying
the SS7 signaling messages.
Time Slot
Number
Integer
0-31
Online
Relevant for Layer2Type=MTP2 only.
Defines the ID of the timeslot used for
carrying the SS7 signaling messages.
MTP2 Profile ID
Integer
0-3
Online
Relevant for Layer2Type=MTP2 only.
Defines the ID of the MTP2Profile that
contains timers and basic MTP2 layer
configuration for specific SS7 Data Link.
Multiple SS7 Data Links may use the same
MTP2 Profile.
Congestion Low
Mark
Integer
0-255
Online
Relevant for Layer2Type=MTP2 only.
Defines the low threshold of the congestion
mark on the SS7 Data Link. When the
transmit queue of a congested link contains
less than the 'Low Mark' messages, a
congestion condition no longer exists.
Congestion High
Mark
Integer
0-255
Online
Relevant for Layer2Type=MTP2 only.
Defines the high threshold of the congestion
mark on the SS7 Data Link. When a link
contains more than the 'High Mark'
messages on the transmit queue, the link is
congested.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...