Version 6.6
487
October 2014
Installation & Operation Manual
38. Configuring the PSTN Subsystem
7.
Create and configure an SS7 Linkset for each
adjacent SS7 signaling node
.
a.
In the Navigation pane, select the SS7 Node configured in step 5.
b.
In the Navigation pane, select
SS7 Linksets
; the SS7 Linksets list is
displayed.
c.
Use the
or
buttons to add or remove entries.
d.
Select a specific row and then in the configuration pane, click
SS7 Linkset
Settings
; the SS7 Linkset Settings screen is displayed.
e.
Configure the SS7 Linkset properties according to the table 'MT3/M3UA -
SS7 Linkset Properties'. Make sure to provision the point code of
adjacent
SS7 signaling node
as Destination Point Code (DPC).
8.
Create and configure an SS7 LinksetLink for each SS7 Data Link configured in
step 1.
Each
signaling link
should be attached to the specific SS7 Linkset (that
is associated with
adjacent SS7 signaling node
).
Note:
Each SS7 Data Link can be attached to one SS7 Linkset only.
a.
In the Navigation pane, select the SS7 Linkset configured in step 7.
b.
In the Navigation pane, select the SS7 Linkset Links; the SS7 Linkset Links
list is displayed.
c.
Use the
or
buttons to add or remove entries.
d.
Select a specific row and then in the configuration pane, click
SS7 Linkset
Link Settings
; the SS7 Linkset Link Settings screen is displayed.
e.
Configure SS7 Linkset Link properties according to the table 'MTP3/M3UA -
SS7 Linkset Link Properties'. Make sure to attach it to the
SS7 Data Link
configured in step 1.
9.
Create and configure an SS7 Routeset for each
destination SS7 signaling
node
.
a.
In the navigation pane, select the SS7 Node configured in step 5.
b.
In the Navigation pane, select
SS7 Routesets
; the SS7 Routesets list is
displayed.
c.
Use the
or
buttons to add or remove entries.
d.
Select a specific row and then in the configuration pane, click
SS7 Routeset
Settings
; the SS7 Routeset Settings screen is displayed.
e.
Configure the SS7 Routeset properties according to the table 'MTP3/M3UA -
SS7 Routeset Properties'. Make sure to provision the point code of
destination SS7 signaling node
as Destination Point Code (DPC).
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......