Version 6.6
911
October 2014
Installation & Operation Manual
D
. Appendix - List of Notification Traps
D
Appendix - List of Notification Traps
The Media Gateway supports the generation of the following notification traps (alarms
and events):
1.
Board Failure Trap - failure of the specific board
2.
Admin State Change - change of administrative state of specific entity
3.
Operative State Change - change of operative state of specific entity
4.
Trunk Alarm - trunk state change alarm
5.
Configuration Error - configuration error
6.
Operational Info - operational information
7.
Voltage Alarm - voltage alarm
8.
Fan Alarm - fan alarm
9.
Temperature Alarm - temperature alarm
10.
Ethernet External Link Alarm - ethernet external link alarm
11.
Ethernet Internal Link Alarm - ethernet internal link alarm
12.
Power Supply Alarm - power supply alarm
13.
Push Button Alarm - push button alarm
14.
Board Temperature Alarm - Media Gateway board temperature alarm
15.
STM 1 Link Alarm - STM 1 link alarm
16.
Board Diagnostics Alarm - board diagnostics alarmBoard Diagnostics Alarm -
board diagnostics alarm
17.
NTP Server Status Changed - NTP server status changed
18.
GW Switchover Alarm - GW switchover alarm
19.
Configuration Change - configuration change
20.
SS7 Activity State Change - change of activity state of SS7 link or linkset
21.
SS7 Local Inhibit State Change - change of local inhibit state of SS7 link
22.
SS7 Remote Inhibit State Change - change of remote inhibit state of SS7 link
23.
SS7 Congestion State Change - change of congestion state of SS7 link
24.
Active Alarm Overflow Trap - overflow of Active Alarms table
25.
Security Alarm – security alarm
26.
Power Entry Module Alarm – alarm on the Power Entry Module (PEM)
27.
Clock Synchronization Alarm – change in state of the PSTN clock
synchronization
28.
External Reference Clock Alarm – alarm on the external PSTN clock reference
29.
Timing Module Alignment Alarm – change in the Media Gateway board’s
alignment to the Timing Module
30.
Board Restart Alarm – indicates that specific Media Gateway board is being
currently restarted
31.
Hardware Error Alarm – hardware error alarm
32.
High Availability Alarm – change in the HA status
33.
Security Event – security event
34.
Line Sync Reference Clock Alarm – alarm on the reference PSTN clock in Line
Sync mode
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...