background image

 

 

 

 

 

 

 

 

 

 

 

 

Manual  
SenzaGate SG151lite 

E-Senza Technologies GmbH | Max-Stromeyer-Str. 116 | 78467 Konstanz | Germany 

Tel.: +49 7531 36599- 10, Fax: +49 7531 36599-29 | [email protected] | www.e-senza.de 

 

 

WWW.INFOPULSAS.LT / [email protected]

Summary of Contents for SenzaGate SG151lite

Page 1: ...ual SenzaGate SG151lite E Senza Technologies GmbH Max Stromeyer Str 116 78467 Konstanz Germany Tel 49 7531 36599 10 Fax 49 7531 36599 29 info e senza de www e senza de WWW INFOPULSAS LT info infopulsas lt ...

Page 2: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment of...

Page 3: ... Explanation of symbols used and signal words The following types of messages provide information about possible property damage and general information concerning proper operation and ease of use The following types of messages provide information about possible property damage and general information concerning proper operation and ease of use SenzaGate is ESD sensitive Wear a grounded wrist str...

Page 4: ... 2 3 9 Edit Deny SenzaBlocks 16 2 3 10 Send AT Command 18 2 3 11 Login Settings 18 2 3 12 Contact 18 2 3 13 Logout 18 2 3 14 Factory Reset 19 3 Technical Information 20 3 1 Battery Backup 20 3 2 Dimensions and mechanical installation 20 4 Technical Support and Training 22 5 Warranty 23 6 WEEE and RoHS Compliance 23 7 CE conformity 24 Copying of this document in full or in part and giving it to oth...

Page 5: ...w of SenzaNET the devices involved terminology and features 1 1 Communication in SenzaNET SenzaGate is the network master responsible for all communication to from the wireless network Hence all communication to any network node is done through the gateway This is possible either via SenzaWMS the SenzaNET programming interface or through Fieldbus interfaces SenzaNET System Overview ...

Page 6: ... interfacing to upper layers SenzaGates are available for a multitude of industrial interfaces Ethernet Serial Modbus Profibus etc SenzaGate SG151lite comes with Ethernet and ModbusTCP interfaces 1 2 3 SenzaWMS SenzaWMS is the software suite accompanying SenzaNET It provides a web based user interface for administration of the wireless network and monitoring of each individual node With SenzaWMS m...

Page 7: ...figuration is done through that same webserver too 2 1 Installation 2 1 1 Electrical and Data Connections SenzaGate is powered by an external 12 V power supply Connect the Ethernet cable now using standard RJ45 connectors 2 1 2 Antenna Connection SenzaGate s IP40 enclosure comes with a reverse SMA antenna connector male and an applicable antenna Just plug antenna onto connector and turn it in cloc...

Page 8: ...to have javascript enabled By default the Gateway will connect via DHCP which means an IP address will be assigned to it by your network s DHCP service If DHCP is not available SenzaGate will be accessible through its default IP address In a LAN network with DHCP SenzaGate can be forced to use the default IP address by unplugging the Ethernet cable during start of SenzaGate and plug it in after 1 ...

Page 9: ...This will bring you to the Login Page 2 3 1 Login Page You need to provide login password to be able to access SG151lite Two logins exist with different access rights 1 Administrator Can use all functionality incl network and SenzaBlock configuration as well as Fieldbus setup and SenzaBlock deny 2 User Can view all information but not change ...

Page 10: ... you can see which interfaces are installed at your SenzaGate the version of the SenzaGate Firmware as well as the MAC ID Note that SenzaGate has two MAC IDs One for wireless communication and another one for Ethernet The Ethernet MAC ID is displayed at the initial screen ...

Page 11: ...are required Field Description Default DHCP enables disables DHCP DHCP enabled IP Address IP of SenzaGate if no DHCP is present 192 168 0 126 Subnet Mask Subnet Mask of the Network if no DHCP is present 255 255 255 0 Ethernet Gateway Address Network Gateway IP 192 168 0 1 For saving these settings you need to press the Save Reboot Button ...

Page 12: ...sable DHCP and assign a fix IP address to your SG151lite because the Modbus Master must be able to find SG151lite at a pre defined IP address The following settings must be made to define the mapping of SenzaBlock data onto Modbus registers Field Description Default Start Address Start address for Modbus 40001 SenzaBlock Sequence List of SenzaBlocks to be mapped onto Modbus registers Each SenzaBlo...

Page 13: ...er 22 Device Status 1 Connected 0 Disconnected Register 23 25 Not used Example for MAC ID 001EAA000000020D SB110 NTC MAC ID Register 1 001E Register 2 AA00 Register 3 0000 Register 4 020D SenzaBlock Type Register 5 0077Hex 119Dec SenzaBlock Type SB110 NTC Sensor Values Register 6 Sensor Value 1 st interface Register 7 Sensor Value 2 nd interface Overflow 1 st interface in case of SB110 PI Register...

Page 14: ...e Sensor 123 SB110 PI 2 channel Pulse Input Metering Applications 130 SB130 4 channel Analog Digital In and or Output The Sensor values Registers 6 9 are hexadecimal numbers representing the measured parameters as follows Temperature values SB110 T HT NTC NTC3 are mapped linearly onto the 2 Byte number range represented by each register 0000 Hex 0Dec 200 C FFFFHex 65535Dec 700 C Humidity values SB...

Page 15: ...face configured to 0 20 or 4 20 mA Pulse counts SB110 PI are directly represented as hexadecimal numbers Since the pulse count can be higher than 65535 two registers are used for each Pulse input channel The Alarm Indicator values Registers 12 and 13 are defined as follows 00Hex 0Dec 00000000Bin no Alarm 01Hex 1Dec 00000001Bin Setpoint Low violated 02Hex 2Dec 00000010Bin Setpoint High violated 04H...

Page 16: ...5 Date Time Setting Date and Time through this webserver page of SG151lite will set the time of SenzaGate and all connected SenzaBlocks The Send Save Button will store Date and Time locally and also trigger a re synchroniation of all SenzaBlocks connected ...

Page 17: ...s well as the communication channels The heartbeat shall be set in accordance with the sampling rate required for your application Keep in mind that this affects the battery lifetime of your SenzaBlocks The shorter the heartbeat the shorter will your battery last Get in touch with E Senza for more detailed information and the battery life that can be expected in your application ...

Page 18: ...Leveraging Power of Wireless Manual SG151lite 14 2 3 7 Show Log This Page is showing the whole log file of the SG151lite it may only be required for debug purposes ...

Page 19: ...ing Power of Wireless Manual SG151lite 15 2 3 8 SenzaBlock Status This Page represents the status of all SenzaBlocks connected and shows their wireless signal strength Linkquality as well as the Battery status ...

Page 20: ...bserver page Commonly this page will be used to setup a SenzaNET during commissioning and you may want to avoid any further SenzaBlocks taking part in network communication if they are not explicitely allowed to do so The Auto deny function is intended for this scenario After commissioning it shall be set to Yes which will cause any new wireless node attempting to join the wireless network being r...

Page 21: ...eless Manual SG151lite 17 When choosing a SenzaBlock for Editing and pressing the Edit button you will be directed to a separate page where settings for this individual SenzaBlock can be made and transmitted to the SenzaBlock ...

Page 22: ... for specialists Refer to the AT command manual for detailed information 2 3 11 Login Settings Here you can modify Login name and password as well as the timeout interval for automatic logout 2 3 12 Contact Contact information for the E Senza Support is provided on this page 2 3 13 Logout Clicking this menu option logs you out from SG151lite and redirects to the Login page ...

Page 23: ...gure below to locate it Use a paperclip to press it which will bring back settings to factory defaults especially IP address settings and login names passwords will be reset to the factory defaults see chapter 2 2 for a list of the default settings Especially in case the IP address was changed and forgotten re setting to factory settings can help ...

Page 24: ...attery on SenzaGate is there for the real time clock on the board If you change the battery Date and Time must be set again This battery lasts for approximately 5 years 3 2 Dimensions and mechanical installation This section shows the dimensions of SG151lite Top view Side view All dimensions in mm ...

Page 25: ...Leveraging Power of Wireless Manual SG151lite 21 SG151lite is a table top model Optionally SenzaGate can be Rail mounted A separate rail mounting kit is available from E Senza Technologies ...

Page 26: ...ts Email support e senza de Phone 49 7531 365 99 19 9am 5pm Central European Time Trainings are available on a regular basis and can be arranged on request as well Visit our website for the latest training schedule http www e senza de en sales training html or get in touch with our team in case of questions or specific training needs training e senza de ...

Page 27: ...ed goods to Buyers plant within Germany This warranty shall not apply to any products E Senza determines have been by Buyer or otherwise subjected to testing for other than specified electrical characteristics or to operating and or environmental conditions in excess of the maximum values established in applicable specifications or have been subject to mishandling misuse neglect improper testing r...

Page 28: ...Leveraging Power of Wireless Manual SG151lite 24 7 CE conformity SenzaGate is authorized for use in Europe USA ...

Reviews: