background image

3561 FC/3502 FC

Vibration Sensor/Gateway

Getting Started Manual

PN 5020149

July 2018

©2018 Fluke Corporation. All rights reserved. Specifications are subject to change without 

notice. All product names are trademarks of their respective companies.

Shop for Fluke products online at:

1.888.610.7664

www.

MyFlukeStore

.com

Summary of Contents for 3502 FC

Page 1: ...d Manual PN 5020149 July 2018 2018 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 2: ...rest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEO...

Page 3: ...cord the asset information 10 In app Setup 11 Step 6 Download and install Fluke Connect 11 Step 7 Complete the in app setup 12 Sensor Installation 14 Step 8 Select the Sensor location 14 Step 9 Confirm the Sensor and Gateway connection 15 Step 10 Mount the Sensors 16 Step 11 Monitor assets remotely 16 Specifications 17 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 4: ...damaged Do not use in wet location Gateway only Table 1 Symbols Symbol Explanation Consult User Documentation W WARNING RISK OF DANGER P Conforms to European Union directives Conforms to relevant Australian Safety and EMC standards Certified by Underwriters Laboratories to North American safety standards Indoor use only Gateway T Double Insulated Gateway This product complies with the WEEE Directi...

Page 5: ...m Description Starter Expansion kits 3502 FC Gateway In Starter Kit only Getting Started Manual 3561 FC Vibration Sensors 4 Epoxy 2 Epoxy application instructions Not pictured Software subscription enabled for Sensors 1 year 3 year Description Gateway 3502 FC Gateway Getting Started Manual VIBRATION SENSOR 3561 FC XXXXX 1 VIBRATION SENSOR 3561 FC XXXXX VIBRATION SENSOR 3561 FC XXXXX VIBRATION SENS...

Page 6: ... Option 1 WiFi connectivity must be available 2 4 GHz at the installation location OR Option 2 Use mobile router hotspot for connectivity For example Verizon Jetpack MiFi Cradlepoint Important For a successful setup follow the sequence in these instructions From the Quick Start page select 3561 FC Vibration Sensor Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 7: ...in the WiFi network name and password 2 Make sure your network complies with these requirements WLAN Standards 802 11 g n GHz Upload speed 1Mbps Sustained Internet HTTP Proxy Disabled Supported Authentication Protocols WEP WPA For a comprehensive list of requirements see Network Configuration Requirement for the FC Vibration Sensor at Shop for Fluke products online at 1 888 610 7664 www MyFlukeSto...

Page 8: ...lant floor production line room where the asset is located Use asset groups to set the asset hierarchy For example Boiler Room Select the test points The Test Point is a specific location on the asset For example Motor Bearing 1 Record the Sensor ID The Sensor ID is the last 5 digits of the unique serial number on the Sensor MFG BLU VISIO N ASSEMBLE D IN CHINA XXXXXXXXXXXXXXXX DFGHJ Y Z X MFG BLUV...

Page 9: ...o 20 from grade to top of motor Vertical pump 8 to 12 from grade to top of motor Vertical pump 5 to 8 from grade to top of motor Vertical pump 0 to 5 from grade to top of motor Horizontal centrifugal end suction pump direct coupled Horizontal centrifugal double suction pump direct coupled Boiler feed pump turbine or motor driven Positive displacement horizontal piston pump under load Positive disp...

Page 10: ...ced draft fan fluid film bearings Vacuum blower belt or direct drive Compressor Reciprocating chiller open motor and compressor Reciprocating chiller hermetic motor and compressor Centrifugal chiller hermetic or open motor Reciprocating air compressor Rotary screw air compressor Centrifugal air compressor with or without gearbox Centrifugal air compressor internal gear axial measurement Centrifuga...

Page 11: ...ft motor Belt drive motor and fan all arrangements Direct drive motor and fan all arrangements Generic Gearbox Single Stage gearbox Machine Tools Machine tool motor Machine tool gearbox input Machine tool gearbox output Machine tool spindle roughing operations Machine tool spindle machine finishing Machine tool spindle critical finishing Shop for Fluke products online at 1 888 610 7664 www MyFluke...

Page 12: ...example see Table 4 Table 4 Asset Information Asset Group Asset Test Point Sensor ID Machine Category Boiler room Chilled Water Pump A Pump bearing 4 DFGHJ 7 Boiler feed pump Boiler room Chilled Water Pump A Pump bearing 3 45T1S 7 Boiler feed pump Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 13: ... Setup Step 6 Download and install Fluke Connect Sign up or sign into the Fluke Connect app Important Complete all steps in this section before you install the Sensor on the asset Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 14: ... 3 On the Home screen tap Setup Logging or Monitoring 4 Follow the in app instructions to complete the setup Important On your mobile phone turn on Bluetooth While connecting the Gateway on the app hold the phone within 4 in 10 cm from the Gateway and follow the prompts 10 cm 4 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 15: ...ce between the Gateway and the Sensor must be 5 ft 1 5 m For step by step guide on in app setup go to Choose 3561 FC Vibration Sensor and download Step by step in app setup guide Important Do not begin the physical installation of the Sensors until the data starts to stream on the graph 10 cm 4 1 5 m 5 Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 16: ...Sensor location Clean the asset by removing chipped paint dust and grease from the surface Important After completing in app setup process wait for a few minutes until the data appears in the session details page Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Page 17: ... the Sensors on the asset test points Do not install them yet 2 In the app make sure you see the alert Sensor is now connected 3 Monitor the the app for several minutes Look for the aler t Sensor has lost connection ο If you do not receive the alert the position is good ο If you receive the alert reposition the Gateway closer to the Sensor Monitor the app again 4 When the Sensor remains connected ...

Page 18: ...g the Sensors Mount the Sensor on solid metal of bearing s of the machine Do not mount on thin covers motor fins electrical boxes couplings or belts Refer to the Deployment Planning Guide on the Quick Start page Step 11 Monitor assets remotely You are now ready to remotely view vibration trends alerts and alarms from your Sensors Epoxy Shop for Fluke products online at 1 888 610 7664 www MyFlukeSt...

Page 19: ...rature trends between 30 C and 80 C 20 F and 176 F Relative Humidity 10 to 95 non condensing Altitude Operating 2000 m Storage 12 000 m Size 2 42 in x 0 95 in 61 5 mm x 24 mm Weight 1 4 oz 28 g Power Battery Type 3 6 V 2400 mAh Lithium Battery Life 3 years typical Bluetooth Type Low Energy 4 1 Range 65 m line of sight during a session Frequency Range 2405 MHz to 2480 MHz Output Power 10 mW IP Rati...

Page 20: ...m Weight 1 2 oz 35 g Power AC Input 100 V ac to 240 V ac 50 60 Hz Bluetooth Type Low Energy 4 1 Frequency Range 2405 MHz to 2480 MHz Output Power 10 mW Antenna 3 dBm Single Antenna Omni Directional WiFi Type 802 11 b g n Frequency Band 2 4 GHz ISM Band Frequency Range 2412 MHz to 2462 MHz Output Power 100 mW Security WEP WPA WPA2 Antenna 0 dBm Single Antenna Omni Directional Signal Strength Less t...

Reviews: