background image

 

ООО "СИМЭНЕРГО" Tel: 8-800-250-77-25 Tel: +7 8442 98-77-25 ICQ: 832220 WWW.SIMENERGO.COM

Summary of Contents for EASYGATE UMTS

Page 1: ...ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 2: ...s should be 0 5 m Do not switch on EasyGate UMTS Data aboard of a plane Do not switch on EasyGate UMTS Data near petrol stations chemical facilities or sites where explosives are used Any mobile telephone use prohibition based on RF energy radiation applies to EasyGate UMTS Data too EasyGate UMTS Data may disturb the function of TV sets radio sets and PCs Warning EasyGate UMTS Data contains compon...

Page 3: ...ly meets customer requirements by improving the firmware For the latest EasyGate UMTS Data processor firmware programming tool and User Manual see www 2n cz For a detailed description of the EasyGate UMTS Data firmware upgrade refer to the section devoted to the PC programming tool ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 4: ...mming 1 pc Dowels 2 pcs Bolts 2 pc CD ROM with User Manual and software 1 pc 2 Quick Installation Guide mounting pattern 1 pc Warranty certificate 1 pc Notes 1 The delivery includes an antenna to be connected directly to the EasyGate UMTS Data SMA connector An antenna with a cable should be used when UMTS GSM signal is poor or in case of interference with other devices 2 Enclosed software EasyGate...

Page 5: ...NG 11 5 VOICE FUNCTION 12 5 1 OUTGOING CALL 12 5 2 INCOMING CALL 12 5 3 AUTOMATIC CALL BABY CALL 13 5 4 TARIFF PULSES 16 OR 12 KHZ 13 5 5 CONFIGURATION OF NETWORK SERVICES 13 5 6 CALL FORWARDING 14 5 7 CALL WAITING 15 5 8 CALL HOLD 15 6 USB INTERFACE 17 6 1 USB INTERFACE DRIVERS INSTALATION 17 6 2 CONNECTION SETTINGS AND START 17 6 3 COMBINATION OF USB TRAFFIC WITH VOICE CALLS 17 7 COM SERIAL INTE...

Page 6: ...perate the system the power supply adapter telephone cable PC serial cable and CD ROM with software Solution for sites without telephone lines such as mountain chalets exhibitions conferences etc CLIP EasyGate UMTS Data is equipped with the FSK based CLIP feature so if a terminal capable of receiving the CLIP is used you know the caller s number Fast internet connection EasyGate uses HSDPA for int...

Page 7: ...uman bodies for electromagnetic interference reasons For the allowed range of operating temperatures refer to the Technical Parameters It is impossible to operate EasyGate UMTS Data on places exposed to direct solar radiation or near heat sources EasyGate UMTS Data is designed for indoor use It may not be exposed to rain flowing water condensed moisture fog etc EasyGate UMTS Data may not be expose...

Page 8: ...nted vertically The Antenna shall be located within the same building as the main equipment For antenna and cable parameters see the Technical Parameters 2 3 USIM Card Installation Use the modern USIM cards designed for UMTS networks to avoid problems Open the USIM card holder on EasyGate UMTS Data s backside insert the USIM card and close it Select the required UMTS provider and USIM card service...

Page 9: ... that is able to display the CLI 2 6 Power Supply Connection EasyGate UMTS Data is fed with 10 16V DC Where a source other than the included power supply adapter is used the voltage range and polarity shown on the EasyGate UMTS Data power supply connector have to be maintained Do not activate the power supply until the antenna is connected to EasyGate UMTS Data to avoid the UMTS module damage 2 7 ...

Page 10: ...2 Telephone Line Tones 3 2 1 Operational Tones EasyGate UMTS Data sends tones to the telephone line to indicate the line status Dial tone continuous or Morse A EasyGate UMTS Data is registered to UMTS GSM network and ready to receive dialing Ringing tone The called subscriber s telephone is ringing The UMTS GSM network transmits this tone Busy tone The busy tone is transmitted in any of the follow...

Page 11: ...2 Programming Mode Tones Tones confirming refusing the values entered are transmitted during telephone line based programming Each tone has a different melody Confirmation Confirms that the service password or parameter number entered is correct and has been accepted Refusal Incorrect parameter number Incorrect parameter value Transmitted when a parameter is cancelled with a Saving Parameter value...

Page 12: ...M card is blocked Use the mobile phone to unblock the USIM card A correctly entered PIN is stored in EasyGate UMTS Data s memory as if you had programmed it using the PCManager The PIN will be entered automatically upon the next EasyGate UMTS Data power up 4 3 Automatic PIN Entering You need not enter the PIN upon power up if it is stored in EasyGate UMTS Data it is entered automatically This func...

Page 13: ...mber is evaluated as complete and transmitted to the network after this timeout 3 A short delay follows the last dialed digit for EasyGate UMTS Data to await further dialing Then the dialing end is signaled and connection is established 4 If the called subscriber is available you can hear the ringing tone If not you can hear the busy tone or any of the provider s messages 5 When the called subscri...

Page 14: ...ifferent prefixes of dialed numbers You can also program EasyGate UMTS Data to transmit tariff pulses as call connect disconnect signaling if your PBX cannot receive telephone line polarity change signaling 5 5 Configuration of network services EasyGate provides some of network services to improve possibility of usage The configuration is done by standard Star Hash codes you can know from mobile p...

Page 15: ...r Call type Deactivation Status check 5 6 2 Call forwarding if busy If this option is activated incoming calls will be forwarded to the configured telephone number if there is call in progress on EasyGate Activation for all call types Telephone number Activation for selected call type Telephone number Call type Deactivation Status check 5 6 3 Call forwarding if no answer If activated incoming call...

Page 16: ...elephone number Call type Deactivation Status check 5 7 Call waiting If the call waiting is activated the incoming call isn t refuse if there is call in progress on EasyGate If there is the other incoming call during connected call it will be indicated by tone See 5 8 for multiple calls management Activation Deactivation Status check 5 8 Call hold Check if your network supports the service before ...

Page 17: ...the active call on hold and accept the held or waiting call switching between two calls dial To place all held calls to active calls and set up conference call dial To connect the two calls active and held and disconnect the EasyGate from both calls dial ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 18: ...ick on it with right mouse button and choose install driver options Follow the instructions up to install drivers for all three interfaces 6 2 Connection settings and start For internet connection create new telephone modem connections using Telit HSDPA USB modem Set up the modem using information from Your mobile operator 6 3 Combination of USB traffic with voice calls When using HSDPA internet a...

Page 19: ...esigned for EasyGate UMTS Data parameter programming It can read configuration data from the memory and store them in EasyGate UMTS Data Moreover all parameters can be saved in your PC file for backup or saving into another EasyGate UMTS Data system ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 20: ...onfirmation tone 5 EasyGate UMTS Data shall remain in the programming mode until hang up 6 Enter the number of the parameter to be programmed and press a If the parameter number is correct you can hear the confirmation tone if not you get the refusal tone and can re enter the parameter number 7 When the parameter number is confirmed enter the allowed parameter value and press a If the parameter va...

Page 21: ...the PCManager is terminated switch the system off and on again 8 2 1 Basic Programming Instructions 1 Run the PCManager and select the language for displaying texts on the right hand side 2 Click on the CD ROM icon for data handling on the left hand side 3 Load data from EasyGate UMTS Data if EasyGate UMTS Data is not in its special programming mode you are invited to switch EasyGate UMTS Data off...

Page 22: ...ing The current EasyGate UMTS Data firmware PCManager and User Manual are available on www 2n cz The latest firmware version is always included in every new PCManager installation Upgrading procedure 1 Run the PCManager select the language for displaying texts on the right hand side 2 Click on the CD ROM icon for data handling on the left hand side 3 Click on the upgrade if EasyGate UMTS Data is n...

Page 23: ...y After connecting EasyGate UMTS Data to PC the program checks the version settings If the version is set wrong the program asks You to change the settings ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 24: ...igits to be dialed It starts to establish connection when this timeout passes Setting options 1 15 s Setting step 1 s Default setting 5 s Minimal On Hook ms Function No The minimum line current discontinuation that EasyGate evaluates as hang up Setting options 100 1500 ms Setting step 100 ms Default setting 500 ms Beep after dialing end Function No Select a beep to signal the end of dialing beginn...

Page 25: ...YES NO Default setting NO Dial tone frequency Hz Function No Setting of frequency frequencies of dial tone Setting options 5 1275 Hz Setting step 5 Hz Default setting 425 Hz Dial tone cadence Function No This tone is generated after Off Hook in case EasyGate is ready to accept dialing Setting options Continuous EasyGate generate continuous dial tone Morse A EasyGate generate dial tone with 320 320...

Page 26: ...es Transmission volume Function No 10 Volume setting for GSM transmission with a 4 dB step Setting options 1 5 Setting step 1 Default setting 3 medium volumelevel Reception volume Function No 11 Volume setting for GSM reception with a 4 dB step Setting options 1 5 Setting step 1 Default setting 3 medium volumelevel 8 3 1 5 Ringing signal settings Ringing signal frequency Hz Function No Ringing sig...

Page 27: ...on No If this parameter is filled the character in the international prefix of CLI is replaced by the defined string The character can neither be transmitted by the FSK protocol nor dialed by the DTMF from a terminal Setting options 0 15 characters 0 9 Default setting blank 8 3 1 6 Automatic call BabyCall number Function No A number to be dialed for the automatic call function If this item is blan...

Page 28: ...tches this prefix The table can contain up to 20 different prefixes There may be exceptions to the rule a number may start with the same digits but has to be served in a different way Any table line that starts with the same prefix followed by one or more digits is considered an exception of the line with shorter prefix Remember to complete the Other numbers line for a number whose prefix is not i...

Page 29: ...the last digit is dialed If the telephone number to be dialed is shorter a timeout is respected The 0 setting means that the function is disabled Setting options 0 3 15 Setting step 1 Default setting 0 End with Function No This parameter enables to establish the call when a is received The character is removed from the dialed number If a should be part of the dialed number this function cannot be ...

Page 30: ... have SMS sending input The parameter telephone number for SMS is common for service SMS and credit checking SMS 8 3 5 GSM UMTS USIM Parameters GSM operator lock Function No Provider blocking is set by manufacturer in EasyGate If EasyGate is blocked to a GSM provider no other GSM provider s SIM card can be used If an unacceptable SIM card is used the GSM modules does not registered to GSM and the ...

Page 31: ...1 Low credit checking in prepaid USIM Time period for low credit checking h Function No Set to change time interval between credit checks If your credit drops under defined value EasyGate sends SMS LOW CREDIT The 0 setting means that the function is disabled Setting options 0 255 h Step 1 h Default setting 0 Code for credit checking Function No Credit in prepaid SIM cards is checked by network fun...

Page 32: ...e first number in text you can leave setting 0 If there are other numbers before credit value set parameter to text position from which the algorithm will seek Setting options 0 180 Step 1 Default setting 0 Telephone number for service SMS Function No Telephone number for service SMS The number is common for GGMC SMS and LOW CREDIT SMS on prepaid SIM cards Setting options 0 16 characters 0 9 Defau...

Page 33: ...le regardless of this setting Time period for GGMC SMS h Function No Time interval for GGMC SMS sending GGMC GSM Gateway Monitoring Centre The 0 setting means that the function is disabled Setting options 0 255 h Step 1 h Default setting 0 Telephone number for service SMS Function No Telephone number for service SMS The number is common for GGMC SMS and LOW CREDIT SMS on prepaid SIM cards Setting ...

Page 34: ...r the PIN code SMS input initialization Function No 93 Initialization of all parameters for SMS sending upon SMS input activation Global initialization Function No 99 Initialization of all EasyGate UMTS Data parameters including the PIN and service password ООО СИМЭНЕРГО Tel 8 800 250 77 25 Tel 7 8442 98 77 25 ICQ 832220 WWW SIMENERGO COM ...

Page 35: ...ne upon EasyGate UMTS Data start the PIN is stored automatically Setting options 0 4 8 characters 0 9 Upon full initialization blank Service password Function No 90 Fill the service password for programming via a telephone line Some parameters can be programmed by DTMF dialing and so the access to programming must be password protected Setting options 4 8 characters 0 9 Upon full initialization 12...

Page 36: ...r line off hook Check the telephone line connection EasyGate UMTS Data is not initialized properly upon start approx 10s after power up EasyGate UMTS Data is not supplied with power EasyGate UMTS Data keeps transmitting a tone during dialing not receiving the dialing Select the correct dialing type DTMF or pulse EasyGate UMTS Data does not communicate with PC Check the serial cable connection Chec...

Page 37: ...board component etc in this context P A BX Private Automatic Branch Exchange PC Personal Computer based on the IBM PC standard PIN Personal Identification Number a USIM card securing password PSTN Public Switched Telephone Network PUK Personal Unblocking Key a password used to unblock a blocked USIM card after repeated wrong PIN entering RS 232C a PC serial port standard USIM Subscriber Identity M...

Page 38: ...230 12V 2A adapter DC power supply 10 to 16V DC 12V consumption Standby 100mA Call max 650mA Data max 950mA Supply connector DC Jack 2 1mm TELEPHONE INTERFACE Interface type 2 wire analog FXS Telephone connector type RJ 12 6 2 Call impedance 600 Ω Loop voltage 48 V DC Loop current max 40 mA Loop resistance max 800 Ω Tone frequency adjustable default 425 Hz Dialing type tone DTMF and pulse Ringing ...

Reviews: