2012 
June 

AY-Q65 

Anti-Vandal Piezo PROX & PIN 
Reader 

Installation and Programming Manual

Summary of Contents for AY-Q65

Page 1: ...2012 June AY Q65 Anti Vandal Piezo PROX PIN Reader Installation and Programming Manual ...

Page 2: ...erty rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give that par...

Page 3: ... AY Q65 14 6 1 Entering Programming Mode 15 6 2 Exiting Programming Mode 15 6 3 Selecting Keypad Transmission Format 15 6 3 1 Keypad Transmission Format Option Number 16 6 4 Selecting Proximity Card Transmission Format 21 6 4 1 Proximity Card Transmission Format Option Number 22 6 5 Changing the Programming Code 22 6 6 Changing the Facility Code 23 6 7 Return to Factory Default Settings 23 6 8 Rep...

Page 4: ...List of Figures iv AY Q65 Installation and Programming Manual List of Figures Figure 1 Drill Holes for AC Q65 Controller 11 ...

Page 5: ...List of Tables AY Q65 Installation and Programming Manual v List of Tables Table 1 Wire Color Guide 12 Table 2 Programming Menus 14 Table 3 Keypad Transmission Format 17 ...

Page 6: ...nfiguration of the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent...

Page 7: ...ers The unit can be programmed to output proximity card data in either 26 Bit Wiegand or Clock Data format The keypad can also be programmed to output eight different data formats The AY Q65 package contains the following items AY Q65 access control unit Installation kit Installation and operating instructions Additional non supplied equipment required Compatible host controller Power supply 5 to ...

Page 8: ... All 26 Bit EM cards Keypad Transmit Format Single Key Wiegand 6 Bit Rosslare Format Single Key Wiegand 6 Bit with Nibble and Parity Bits Single Key Wiegand 8 Bit Nibbles Complemented 4 Keys Binary Facility Code Wiegand 26 Bit 1 to 5 Keys Facility Code Wiegand 26 Bit 6 Keys BCD and Parity Bits Wiegand 26 Bit Single Key 3x4 Matrix Keypad 1 to 8 Keys BCD Clock Data LED Control Input Dry Contact N O ...

Page 9: ...ing Manual 9 Environmental Characteristics Operating Temp Range 25 F to 145 F 32 C to 63 C Operating Humidity 0 to 95 non condensing Suitable for outdoor use meets IP65 Dimensions Length x Width x Depth 4 72 x 3 x 0 85 in 120 x 76 x 22 mm Weight 0 97 lb 440 g ...

Page 10: ... 26 Bit Built in piezoelectric keypad for PIN code entry Programmable keypad transmission format Built in case and back tamper Tamper output LED Control Input Programmable Facility Code Two tri colored LEDs Internal buzzer provides audible interface feedback Comes with mounting template for easier installation Comes with installation kit that includes a security screw and a security screw tool ...

Page 11: ...er specifically aligned for the US Gang Box see A in Figure 1 For a four screw custom installation there are four indicators on the back see B in Figure 1 Figure 1 Drill Holes for AC Q65 Controller 2 Route the interface cable from the reader to the controller A linear type power supply is recommended 3 Screw the AY Q65 back cover to its mounting location 4 Return the front cover of the AY Q65 to t...

Page 12: ...repare the controller cable by cutting the cable jacket back 1 inches and strip the wire inch 2 Splice the reader pigtail wires to the corresponding controller wires and cover each connection see Table 1 Table 1 Wire Color Guide Color Description RED VDC BLACK GROUND WHITE Data 1 Clock GREEN Data 0 Data BROWN LED Control PURPLE Tamper 3 If the tamper output is being utilized connect the purple wir...

Page 13: ...reader is in Transmit Mode the Transmit LED is red and the Program LED is off When a proximity card or keyboard entry is being transmitted the Transmit LED flashes green Keyboard data can be sent via one of eight different keypad transmission formats see Section 6 3 Proximity cards presented to the reader are always sent in either Wiegand 26 Bit or Clock Data formats see Section 6 4 Transmit Progr...

Page 14: ...of all the AY Q65 menus Default factory settings are marked by an sign Table 2 Programming Menus Menu Description Menu Number Selecting Keypad Transmission Format Single Key Wiegand 6 Bit Rosslare Format Single Key Wiegand 6 Bit with Nibble Parity Bits Single Key 8 Bit Wiegand Nibbles Complemented 4 Keys Binary Facility code Wiegand 26 Bit 1 to 5 Keys Facility code Wiegand 26 Bit 6 Keys BCD and Pa...

Page 15: ...within 30 seconds the AY Q65 returns to Transmit Mode 6 2 Exiting Programming Mode To exit Programming mode at any time 1 Press the key You hear a beep The Program LED turns off and the Transmit LED turns red This indicates that the AY Q65 has returned to Transmit mode Wrong entries may reset the reader back to Transmit mode While in Programming mode if no key is pressed for 30 seconds the AY Q65 ...

Page 16: ...urns red If an incorrect option number is entered a long beep is sounded The reader returns to Transmit mode and the keypad transmission format remains unchanged Only one keypad transmission format can be active at any one time When using the keypad transmission format 1 to 8 keys BCD Clock Data Option 8 an additional input is required to specify the number of keys in the PIN code 6 3 1 16BKeypad ...

Page 17: ...erent keypad transmission formats is available below and on the following pages 6 3 1 1 Single Key 6 Bit Wiegand Rosslare Format Each key press immediately sends 4 bits with 2 parity bits added even parity for the first 3 bits and odd parity for the last 3 bits 0 1 1010 0 6 1 0110 0 1 0 0001 0 7 1 0111 1 2 0 0010 0 8 1 1000 1 3 0 0011 1 9 1 1001 0 4 1 0100 1 1 1011 1 B in Hexadecimal 5 1 0101 0 0 ...

Page 18: ...umber four and can be in the range 000 to 255 The factory default setting for the Facility code is 000 see Section 6 6 The keypad PIN code must be 4 digits long and can range between 0000 and 9999 On the fourth key press of the 4 digit PIN code the data is sent across the Wiegand Data lines as binary data in the same format as a 26 Bit card If the key or the key are pressed during PIN code entry t...

Page 19: ...a 26 Bit Card If the key or the key are pressed during PIN code entry or a PIN code greater than 65 535 is entered the keypad clears the PIN code entry buffer generates a beep and is ready to receive a new 4 digit keypad PIN code If the entry of the 1 to 5 digit keypad PIN code is disrupted and no number key or key is pressed within 5 seconds the keypad clears the PIN code entry buffer generates a...

Page 20: ...e proximity card readers 26 Bit Wiegand or Clock Data formats active An optional interface board must be used between the AY Q65 and the host system Each key press is immediately sent on DATA0 as an ASCII character at a baud rate of 9600 bits per second When a key is pressed DATA1 is pulled low until the key is released at which point DATA1 is set to high This allows the controller to detect the d...

Page 21: ...clears the PIN code entry buffer generates a beep and is ready to receive a new keypad PIN code If the entry of the digit keypad PIN code is disrupted and no number key or key is pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new keypad PIN code 6 4 Selecting Proximity Card Transmission Format The AY Q65 has two differe...

Page 22: ...ption Number 26 Bit Wiegand Wiegand 26 Bit transmission format select option 1 Clock Data Clock Data transmission format select option 2 6 5 12BChanging the Programming Code To change the Programming code 1 Enter Programming mode 2 Press 3 to enter Menu 3 The Transmit LED turns red 3 Enter the new 4 digit code you wish to set as the Programming code Three beeps are emitted on success The system re...

Page 23: ...Three beeps are emitted on success The system returns to Transmit mode The Program LED turns off and the Transmit LED remains red Facility codes can be in the range between 000 and 255 6 7 14BReturn to Factory Default Settings You must be very careful before using this command Doing so erases the entire memory which includes all user and special codes In addition all codes are returned to their fa...

Page 24: ...r a long beep and the controller returns to Normal mode without erasing the memory of the controller 6 8 Replacing a lost Programming Code In the event that the Programming code is forgotten the AY Q65 may be reprogrammed in the field using the following instructions 1 Remove power from the reader 2 Activate the tamper by removing the reader from the wall or removing the reader s case 3 Apply powe...

Page 25: ...he price of the Product paid by Customer provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty Unless otherwise requested by a ROSSLARE representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the del...

Page 26: ...cost to the repair center removal or reinstallation of the product whether or not proven defective Specifically excluded from this warranty are any failures resulting from Customer s improper testing operation installation or damage resulting from use of the Product in other than its normal and customary manner or any maintenance modification alteration or adjustment or any type of abuse neglect a...

Page 27: ...mplied warranties of merchantability and fitness for a particular purpose are specifically excluded In no event shall ROSSLARE be liable for damages in excess of the purchase price of the product or for any other incidental consequential or special damages including but not limited to loss of use loss of time commercial loss inconvenience and loss of profits arising out of the installation use or ...

Page 28: ... 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 support na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support...