background image

Silo

Patrol

®

Radar

Right

TM

Inventory Monitoring Systems

Silo

Track

TM

CLOUD

Gateway

(6-87xx-xxx)

B U L L E T I N

3 9 4 A

I N S T A L L A T I O N   &   O P E R A T I O N

www.monitortech.com

Gateway

®

Thank you for purchasing a quality product from Monitor Technologies LLC. We

realize that you do have a choice of vendors when procuring level measurement

equipment and we sincerely appreciate your business!
This manual contains the information necessary to ensure a safe and successful

installation. Please read and comply with the section of this manual pertaining to

SAFETY. Doing so will ensure proper operation of the equipment and the safety

of all personnel.
Before discarding shipping container, please inspect it thoroughly and verify that

all parts ordered are accounted for.  Sometimes smaller parts become stuck under

carton flaps and other packaging materials.
In the event that information contained herein does not completely satisfy your

requirements or answer your questions, you may contact Technical Support on our

website www.monitortech.com, by telephone at 800-766-6486 (630-365-9403), or

by e-mail at [email protected]. If your product ever requires service

either in or out of warranty, please contact us and obtain an RMA (Return Material

Authorization) number prior to shipping the unit to us. 

Shown with

standard

antenna

NOTE:

User Manuals for

Silo

Track

TM

CLOUD 

are available through

the application at:

www.mysilotrackcloud.com

Summary of Contents for SiloTrack CLOUD

Page 1: ...and the safety of all personnel Before discarding shipping container please inspect it thoroughly and verify that all parts ordered are accounted for Sometimes smaller parts become stuck under carton flaps and other packaging materials In the event that information contained herein does not completely satisfy your requirements or answer your questions you may contact Technical Support on our websi...

Page 2: ...lculated volume and weight values are affected by variations in actual vessel dimensions angle of repose fluctuation in material bulk densities material flow properties rat holes bridging etc vessel inlet discharge location s and location of the sensor on the vessel The direct distance measurement made by the SMU is from the bottom of the SMU mounting flange to the point on the plumb bob The direc...

Page 3: ...ors any combination of SiloPatrol SMU RadarRightTM sensors that are allowed on the network The SiloTrackTM CLOUD Gateway continuously monitors the status of each sensor via a multi dropped RS 485 communication link Each sensor has to be uniquely addressed with a value from 1 247 though we recommend using 1 32 for simplicity of the overall installation Communication failures on the RS485 network an...

Page 4: ...rder to maintain the NEMA 4X and IP65 rating of the enclosure 5 Cable Entry Machining Machine cable entries into the enclosure s exterior where desired The recommended method is with a hole punch sized for the desired fitting A hole saw or drill bit can also be used 6 Mounting Secure the enclosure to the wall with size 10 fasteners thru the slotted holes in the mounting brackets See Figure 1 7 Re ...

Page 5: ... not important use shortest cables as possible while avoiding T s and star configuration in your wiring Communication networks such as this operate best when the interconnection has only two ends Observe polarity when making the communication interconnection D and D as this system does not have auto adjusting polarity functions Attach cable shield in terminal provided 0V 7 Master Device The SiloTr...

Page 6: ... LED OFF no power applied to router LED ON power applied to router SERVICE LED WWAN network status LED OFF no WWAN network connection LED ON WWAN network connected LED FLASHING WWAN traffic being transmitted or received SIGNAL LED RF Cellular strength 3 LED s excellent 2 LED s good 1 LED fair 0 LED s poor or no signal Figure 4 Router Status LED s 3 3 SiloPatrol SMU or RadarRight Sensor Configurati...

Page 7: ... excessive operation can affect optimum performance and or useful life However there are no physical limitations to the number of operations which can occur in one hour i e the motor can run continuously and not overheat For a fully continuous measurement device consult the factory regarding other technologies such as RadarRight non contact radar sensor 2 Measurement rate The average measurement r...

Page 8: ...rn to home position verify that the wiper seal is not fouled with material Excessive drag on cable can cause premature cycle stoppage PROBLEM SiloTrackTM CLOUD Gateway reports an Index Error on a specific channel CAUSE SOLUTION 1 This error is caused by the measurement of upward travel distance of an SiloPatrol SMU plumb bob being greater than the downward travel distance 2 Determine if error is r...

Page 9: ...terial and workmanship under normal use and service for two 2 years from the date of purchase The purchaser must notify Monitor of any defects within the warranty period return the product intact and prepay transportation charges The obligation of Monitor Technologies LLC under this warranty is limited to repair or replacement at its factory This warranty does not apply to any product which is rep...

Page 10: ... L L E T I N 394A JCS JSS MAY 01 2020 DOC 001 394A 1 Monitor Technologies LLC 44W320 Keslinger Rd t Elburn IL 60119 t 1 630 365 9403 t 1 800 766 6486 t E mail monitor monitortech com t www monitortech com ...

Reviews: