Version 6.6
261
October 2014
Installation & Operation Manual
29. Working with the ES Boards
29
Working with the ES Boards
The Ethernet Switch (ES) boards provide IP network connectivity for all of the boards
inside the Mediant 8000 chassis (i.e., the SC and Media Gateway boards.
29.1
ES Redundancy Mode
There are two ES boards in the chassis. Each board should be independently
connected to the external IP network. The two ES boards operate in an asymmetric
1+1 redundant mode. At any time, one of the ES boards is Active and provides
connectivity for the rest of the chassis' boards, while the other ES board is Standby.
When the Active ES board fails, the Standby ES board takes over activity and
becomes the Active ES board.
An Internal link (F-Link) interconnects between the two ES boards and provides
internal communications between the boards inside the chassis.
29.2
ES Boards in the EMS
In the EMS, the Active ES board is colored
black
and the Standby ES board is colored
blue-gray
. The ES board in slot 9 is initially the Active ES board (upon chassis power
up) and the ES board in slot 19 is initially the Standby ES board.
Figure
29-1: ES Boards in the EMS
The status of the ES boards is represented by standard
Operational State
,
Administrative State
and
Severity
attributes.
When the ES board is functioning properly, its
Operational State
is set to
Enabled
,
Severity
is set to
Clear
and in the EMS the board is colored
green
.
When the ES board's functionality is degraded, an alarm indicating the problem
details is generated and the board's Severity is set according to the alarm's
severity. In the EMS, the board is colored
blue
,
yellow
or
orange
, according to the
Severity value.
Summary of Contents for Mediant 8000
Page 2: ......
Page 33: ...Part I Hardware Overview This part describes the hardware overview of the Mediant 8000 chassis...
Page 34: ......
Page 90: ......
Page 158: ......
Page 264: ......
Page 546: ......
Page 775: ...Part VI Maintenance This part describes the Mediant 8000 maintenance procedures...
Page 776: ......
Page 834: ......
Page 879: ...Part VIII Appendices This part describes additional Mediant 8000 configuration procedures...
Page 880: ......
Page 924: ...Media Gateway Mediant 8000 www audiocodes com Installation Operation Maintenance Manual...