Operation manual - EN
www.atmos.eu
EN - 44
ACD03/04
After setting (planning), switch on the automatic wood ignition function
by pressing the green
START button.
CAUTION – Before confirming, check the retracted (closed) ignition valve and the
properly closed and secured door (locking screw) and cleaning apertures.
If the function is activated properly, the automatic wood ignition icon is displayed on the main
screen next to the flashing hand button . The information icon
i
shows an overview of the plan and
the status (on/off) of the ignition spiral.
When the automatic ignition of wood is started, the boiler exhaust fan and the ignition spiral are tur-
ned on. Everything is indicated by the flashing of the automatic ignition symbol next to the hand
symbol button .
7. Buttons and information on the screen