10. Setting menu - Hydraulics
/Communication
Controlled circuit -
the button allows you to change the default setting (assignment) of the relevant
heating circuit to the relevant room unit.
Predefined default setting:
- Circuit 1 is predefined for the ARUa unit
- Circuit 2 is predefined for the ARUb unit
- Circuit 3 is predefined for the ARUc unit
- Circuit 4 is predefined for the ARUd unit
- Circuit DHW is predefined for the ARUe unit
INFO
- Circuits can only be assigned to room units if they are defined as DK or MK.
ATTENTION
- For the
ARU10
room unit (unit without display), it is
possible to select
only one circuit to be controlled under the Controlled circuit button.
If control of more circuits by the ARU10 unit is required, the additional circuits must be set
as
Dependent
on the circuit currently assigned to the unit. The setting of the dependence is
performed in the
→
Hydraulics / Function configuration / Heating circuit functions /
Type of connection to the circuit menu.
For the
ARU30
room unit, it is possible to select
more circuits
under the
Controlled circuit
button, which will be displayed on the room unit display and for which we can change the
required room temperatures (Comfort temperature , Setback temperature ).