Operation manual - EN
www.atmos.eu
EN - 36
ACD03/04
DCxxSP(X), DCxxGSP combined boilers (manual / automatic)
For DCxxSP(X), DCxxGSP combined boilers, where the pellet burner is permanently
installed in the lower (third) chamber, it is possible to select either
manual
switching
or
automatic switching
of operation after wood burnout. This depends on the
→
P23
Boiler
Parameter setting.
Manual switching
(P23
Boiler
Parameter =
1-manually
) - switching
from manual heating
(stoking)
to automatic heating
with burner is performed by holding down the button with the
hand symbol
for
more than 3 seconds.
If the boiler is not in operation (not burning), the flue gas temperature is lower than the AGFmin
minimum flue gas temperature defined by
→
P18
Boiler
Parameter, the source will be switched
immediately and
in case of heating system demand
the burner is switched on (started).
3 s
7. Buttons and information on the screen