ACD03/04
12. Overview of menus and their parameters
SOLAR HEATING menu
Parameter Description
Setting range / Setting value
Factory default setting
Setting
P01
Switching difference
8 - 30 K
10 K
P02
Shutdown difference
2 - 7 K
5 K
P03
Minimum SOLP pump operation time
1 - 10 min
3 min
P04
SZV switching temperature
Off
P05
Requested temperature of sol. KSPF tank
20 - 110 °C
75 °C
P06
Solar circuit operating mode
1 – parallel
2 – priority
3 – priority TUV
4 – priority PF
1 – parallel
P07
Automatic boiler blocking
Off
P08
Parallel / priority mode switching
10 - 50 K
Off
P09
Solar gain balance
Off
P10
Solar gain RESET (zeroing)
P11
Solar circuit flow value
0,1 - 30,0 l/min
0,1 l/min
P12
Media density
0,80 - 1,20 kg/l
1.05 kg/l
P13
Thermal media capacity
2,0 - 5,0 kJ/kgK
3.6 kJ/kgK
P14
Solar panel shutdown temperature
25 - 210 °C
Off
P15
SLV switching period
10 - 60 min
10 min
P16
Required SLVF sol. tank temperature
20 - 110 °C
60 °C
P17
KLV switching period
10 - 60 min
10 min