Table of max. cable length for supply voltage drop of approx. 3 V:
diameter (cross section) of the supply line
cable length max
0,6 mm (0,28 mm
2
cross-section)
100 m
0,8 mm (0,5 mm
2
cross-section)
200 m
Recommended cable type:
J-Y(ST)Y 2x2x0,8 cross-section 0,5 mm
2
- order code: S0659
General circuit diagram of the connection
ATTENTION
- ARU30 spring terminals do not allow to intentionally connect two lines to
one terminal
(one line = one terminal)
.
Other room unit for
heating circuit 2
Other room unit for
heating
circuit 3
ACD 03/04
GND
B
+12 V
PE
A
ARU30
ARU30
ARU30
GND
GND
GND
A
A
A
B
B
B
+12 V
+12 V
+12 V
+12 V
+12 V
+12 V
A
A
A
B
B
B
GND
GND
GND
ARU30 - for heat-
ing circuit 1
Data bus
Data bus
Data bus
Data bus
31 32 33 34
ARU30
ACD 03/04
GND
B
+12 V
PE
A
ARU30
GND
A
B
+12 V
+12 V
A
B
GND
ARU30 - for heating
circuit 1
Other room unit for
heating circuit 2
Other room unit for
heating
circuit 3
Data bus
Data bus
31 32 33 34
ARU10
ARU10
A
A
+12 V
+12 V
B
B
GND
GND
Data bus
Data bus
Source
12 V (4 - 8 VA)
supply
230 V / 50 Hz
supply
230 V / 50 Hz
Other room unit
for heating
circuit 2
Other room unit
for heating
circuit 3
N
N
L
L
ACD 03/04
GND
B
+12 V
PE
A
ARU30
ARU30
ARU30
GND
GND
GND
A
A
A
B
B
B
+12 V
+12 V
+12 V
+12 V
+12 V
+12 V
A
A
A
B
B
B
GND
GND
GND
ARU30 - for heat-
ing circuit 1
Data bus
Data bus
Data bus
Data bus
31 32 33 34
Source
12 V
(4 - 8 VA)
Source
12 V
(4 - 8 VA)
Pay attention
to the maximum output load of 12 V on the ACD 03/04 controller
BUTTONS AND INFORMATION ON THE DISPLAY
(default screen)
Current outdoor temperature
(minimum / maximum)
in 24 hours
Date and time
Button to switch
between heating
circuits
Antifreeze
protection
-or summer mode
Heating circuit
name
Current mode
Flame icon representing information
about the operation of the source
Time program for the
heating circuit
Relative air
humidity
Information on correct communication
( wire version / wireless version)
Current room
temperature for the
relevant heating
circuit
Button to enter the
Information menu
Button to enter the
Settings menu
BUTTONS AND INFORMATION ON THE DISPLAY
The following information is displayed directly on the touch screen:
- Current room temperature for the relevant heating circuit
- Heating circuit name
- Information on proper communication
- Time program for the relevant heating circuit - current day (ongoing)
The orange segments show the desired operation set to COMFORT temperature , the white
ones to SET BACK temperature
- Button to switch between heating circuits
Using the arrows , it is possible to briefly display (10 s) the room temperature (time program)
read by other room units connected (paired) to the ACD03/04 controller. It is also possible to
display the domestic hot water temperature (if read).
- Relative air humidit
Relative humidity is only measured at room temperatures higher than 0 °C.
- Current outdoor temperature
- Minimum / maximum outdoor temperature in 24 hours
13. R
oom units
Summary of Contents for ACD 03
Page 1: ...Operation manual EN www atmos eu EN 1 ACD03 04 Operation manual ...
Page 2: ...Operation manual EN www atmos eu ACD03 04 ...
Page 8: ...Operation manual EN www atmos eu EN 8 ACD03 04 ...
Page 265: ...Operation manual EN www atmos eu EN 265 ACD03 04 12 Overview of menus and their parameters ...