The planned start
can be easily cancelled. Press and hold the button with the hand symbol for
more than 3 seconds or enter
the automatic wood ignition menu
via the
→
button. To cancel
the automatic wood ignition, press the red
Yes/STOP
button.
The operation information about the automatic wood ignition can be found in the
i
Information
menu.
INFO –
If the ignition failed (flue gas temperature did not exceed 80 °C
→
Parameter
P18
Boiler
), the boiler will be shut down after the ignition time has elapsed (60 min -
→
Parameter P08
Boiler
). Information about a failed ignition is displayed in
i
Information – Wood
ignition failed!
3 s