39
Sets the maximum time to fill the storage tank with water (hot and/or
cold).
Sets the filling time for the detergent liquid when the water in the storage
tank is filled up to the low level.
Sets the filling time for the detergent liquid when the water in the storage
tank is filled up to the high level.
Sets the language used to display messages on the display between the
two ones available on-board the machine.
Enable or disable the buzzer to signal the end of the wash cycle.
This sets the temperature value at which the door can be opened.
This sets the temperature value at which the “Steam Solenoid Valve”
output trips.
Minimum temperature value that must be maintained during disinfection.
Maximum temperature value that must not be exceeded during
disinfection.
This sets the time that the solvent pump operates.
This sets the time the solvent is left to work.
This sets the time the door takes to open up at the end of the cycle.
This sets the unit of measure of the ventilation system expressed in
seconds or minutes.
Time value for which the ventilation system works.
This enables or disables the self-disinfection system; we choose the wash
program used for self-disinfection.
Water fill timeout
____ min.
Detergent time L1
____ s
Detergent time L2
___ s
Language
Italian / English
Buzzer
ON / Off
Opening Temperature
°C
Steam SV Temp.
°C
Minimum hysteresis
°C
Maximum hysteresis
°C
Solvent Time
s
Solvent Action
s
Door Opening Time
s
A_System
Sec/Min
A_System Time
s
Self-disinfection
OFF/Program X