5.3
MACHINE SETUP SPECIFICATIONS
MODIFYING THE WASH PHASES (programs 1-7)
Use keys 3 and 4 to modify the duration of the first phase of the wash cycle
(hot, cold or mixed).
Vary the duration of the second phase and, subsequently, all the other phases
no matter what they are, using the same process (using keys 3 and 4).
Phases can be from one to twelve. All their duration times can be varied as just described.
Changing this parameter changes the operation time of the softener pump
(using keys 3 and 4).
This parameter sets the temperature that will be maintained in the basin to
perform disinfection of the items being processed.
These settings can be done for all the programs that exist on-board the machine. The program to modify
must be selected from the main menu before setting the above-described parameters.
CLOCK
Used to set the current time
MISCELLANEOUS PARAMETERS
Defines a value which, added to the disinfection temperature value, sets
the maximum temperature value in the wash chamber. The machine must
not operate when this value is exceeded.
Sets the number of wash cycles that the machine will perform before
making a request for routine maintenance.
Sets the maximum time for reaching the disinfection temperature in the
wash chamber. This time starts to count when the cycle starts.
This sets the maximum time for which the machine must maintain a
Temperature of 85°C.
Phase 1 time
__ s
Phase 2 time
__ s
Set disinfection T
__ °C
Softener time
__ s
Temp. alarm Delta
__ °C
N° Cycles for Service
____
Heating timeout
_____ min
Disinfection Timeout
____ min
Clock
XX/XX/XX XX:XX