28
© 2021 United States Stove Company
VERTICAL TERMINATION
CONFIGURATIONS
The following three figures show the three different
configurations for vertical termination.
Vertical Rigid Venting Configuration
using Three (3) 90° Elbows with two
(2) Horizontal runs
V
H
1
H
Venting with Two (2) 90° Elbows
Maximum Horizontal
(H + H¹)
Minimum Vertical (V)
24” (610 mm)
44-3/4” (1137 mm)
20” (6m)
98-3/4” (2508 mm)
H
V
V
1
Vertical Rigid Venting
Configuration using
Two (2) 90° Elbows
Venting with Three (3) 90° Elbows
Maximum Horizontal
H + H¹
Minimum Vertical (V)
24” (610 mm)
52-1/2” (1334 mm)
20” (6m)
98-3/4” (2508 mm)
V
Vertical Rigid Venting
Configuration with
No Horizontal Run
VENTING INSTALLATION