background image

INSTALLATION and  
OPERATING INSTRUCTIONS

PELLET STOVE  
MYSINGE

Summary of Contents for MYSINGE

Page 1: ...INSTALLATION and OPERATING INSTRUCTIONS PELLET STOVE MYSINGE ...

Page 2: ......

Page 3: ...er from the burner housing and remove any ash from the ash box unburned pellets must not be emptied into the ash box there is a risk of them starting to smoulder After a period of operation the glass in the door becomes coated with ash dust and eventually becomes opaque It should be wiped off from the inside using kitchen roll moistened with normal tap water we recommend that this is done each tim...

Page 4: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 4 24 ...

Page 5: ... stove has been developed to work as a primary heat source The stove s high level of efficiency in combination with automatic operation means that the stove replaces up to 80 of the heating in a normal family house with electricity as heating source The stove is designed for firing with wood pellets and requires an electrical power supply In the event of a power failure the stove requires power fr...

Page 6: ... The ash box 12 is inset in the bottom of the hearth under the burner housing It can be removed when the door has been opened The combustion fan 13 is placed on the rear of the burner housing and provides the burner with air for combustion The control circuit board 15 is placed inside the stove and contains a transformer for 12V voltage to the electronics and control and supervision The hot air fa...

Page 7: ...re Explanatory text scrolls through the display every 5 seconds The adjustment dial is used by pressing or turning Turn to scroll through the menu or change the value when adjusting Pushing once makes a selection in the menu Example Connect the stove to the wall socket Pressing once causes the panel to ask Start Pressing again means that you confirm the question and the stove starts If you turn cl...

Page 8: ...s 2 Hook one corner of the panel onto the wall mounting 3 Press the other corner of the panel onto the wall mounting Removing the control panel 1 Slide the panel straight up 2 Lift the panel straight out from the wall 1 2 3 1 2 Connecting the control panel Connect the control panel in the modular connection on the side of the control circuit board image ...

Page 9: ...ded for authorised installers Turn the dial to scroll through the menu To jump out of the menu hold the button in for 4 seconds The menu appears as follows Main menu Start Stop Confirm by pressing once to start stop Stop T Press to select and adjust desired stop temperature Usermenu Press for Usermenu Back Press for display Usermenu Settings SetCode 021 Settings Press for Settings Service Menu for...

Page 10: ... the set values HIGH OUTPUT After START HiPower scrolls through the display The feeder runs according to FeedHi Combustion fan Fan HI The time depends on the set fuel amount at high output Every 10 seconds Set temperature and room temperature are compared If the room temperature falls below the set temperature by less than 1 C the program switches to low output The flame sensor is checked If no fl...

Page 11: ...e temperature of adjacent building parts may not exceed 80 C Minimum diameter round duct or side rectangular duct should be 80 mm The smoke ducts must be made of non flammable material of sufficient durability and with sufficient resistance to temperature variations climate effects corrosive smoke gases and slag and use of sweeping tools etc It must be possible to clean the flue If fallen ash cann...

Page 12: ...on Warranty and Installation proof Manufacturing number Installation date Vacuum in chimney cold Vacuum in chimney hot Outdoor temperature Smoke gas temp at max operation Carbon dioxide content CO2 Distance to combustible material Trafo 230 VAC J3 J4 J1 J8 J5 J10 RS485 J6 J9 PE röd vit orange orange 1 2 6 7 9 1 0 4 5 230 VAC M brown grey Convector fan Feeder motor black blue white blue Safety swit...

Page 13: ... must be restarted again 3 2 Ash removal The amount of ash that build up in the burner varies depending partially on how the stove is fired number of starts and stops division between full and half speed and partially on the quality of the pellets The ash content varies between different pellets but can also differ between different batches from the same factory This can only be established throug...

Page 14: ...d out a couple of times annually after removing the side hatch Do not forget to pull the plug out before the side hatch is removed The side hatch is secured using two panel screws that are visible when the filling hatch has been opened After the screws have been removed the upper section of the side hatch is pulled straight out and hooked onto the side member NOTE When vacuuming the hot air fan be...

Page 15: ...perature Increase Stop T above 30 C to start in On mode When the room temperature has exceeded 5 C adjust the desired stop temperature Condensation leaks from the stove s flue connection Flue smoke too cold for the chimney Increase the output by adjusting the amount of fuel and air Deactivate low output Insulate the chimney Install condensation trap Smoke odour Blocked smoke access Contaminated co...

Page 16: ...er auger Check switches and wiring to the motor Replace motor Powfail Power failure Too much ash in the burner Check the electrical connection Sweep your stove once a week during the firing season Errign The firing element is not drawing any power Poor contact to firing element Defective firing element Check wiring and connections Replace firing element ErrSafe The flame sensor has not detected a ...

Page 17: ... the terminal block 4 Slacken off the screw 3 that secures the firing element Remove the firing sleeve from the element Pull out the cables from the lead ins 5 Reinstall in reverse order 4 3 Combustion fan 1 Remove the burner and the ignition console according to the Firing element section 2 Remove the red and the blue cable from the terminal block on the side of the bracket 3 Remove the screws 2 ...

Page 18: ... Control circuit board 1 Remove the plug from the wall socket 2 Remove one of the side hatches according to the Hot air fan section 3 Remove the edge connectors on the long sides of the control circuit board by pulling them straight out from the circuit board 4 Disconnect the cable for the control panel located in a connector on one edge of the control circuit board Press in the hook on the unders...

Page 19: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 19 24 5 Warranty For warranty issues Ariterm Sweden AB refers to our local Distributor ...

Page 20: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 20 24 ...

Page 21: ...PELLET STOVE KMP MYSINGE ARITERM SWEDEN AB Installation Instructions 2010 05 20 21 24 Declaration of conformity ...

Page 22: ......

Page 23: ......

Page 24: ...r www ariterm se If these instructions are not followed at installation operation and maintenance Ariterm Sweden AB s applicable warranties are not binding Ariterm reserves the right to make changes to components and specifications without prior notice ...

Reviews: