24
© 2021 United States Stove Company
VENTING INSTALLATION
Install Vinyl Siding Standoff
HOT
Apply Mastic
to All Four
Sides
Cut Vinyl Siding Away
to Fit Standoff
Wood Screw
Vent
Cap
Bolt
Nut
Standoff
HOT
Vent Cap
Wood Screw
Apply Mastic
to All Four
Sides
Install Horizontal Vent Cap
HOT
H
V
Horizontal Termination
Configuration for Rigid
Venting Using One (1)
90° Elbow
Horizontal Venting
Maximum Horizontal (H)
Vertical Minimum
24” (610mm)
54-1/2” (1384)
20” (6m)
102-1/4” (2597mm)
NOTE: Add 1/4” rise per 12” horizontal length of
pipe.
NOTE: This configuration is for use with corner
installation also.
H
1
H
V
Horizontal Termination
Configuration for Rigid
Venting Using Two (2)
90° Elbows
Horizontal Venting with Two (2) 90° Elbows
Maximum Horizontal
H + H¹
Vertical Minimum
24” (610 mm)
54-1/2” (1384)
20” (6m)
102-1/4” (2597 mm)
NOTE: Add 1/4” rise per 12” horizontal length of
pipe.