CLEARANCES
US Stove highly recommends your stove be
installed by a qualified NFI (US) or WETT
(Canada) technician. To find the nearest
qualified installer, go to:
https://nficertified.org
,
https://www.wettinc.ca/
CLEARANCES TO COMBUSTIBLES
The dimensions shown in the figures are minimum
clearances to maintain when installing this heater.
Left and right clearances are determine when facing
in front of the heater. Follow these instructions
carefully to ensure a safe installation Failure to
follow instructions exactly can create a fire hazard.
The appliance cannot be installed directly on
carpet. If installed on carpet, the appliance shall be
installed on metal, wood or other non-combustible
material panel extending the full width and depth
of the appliance. Clearances are in accordance with
local installation codes and the requirements of the
gas supplier.
B
A
C
D
D
E
F
in
mm
A Backwall to Fan Enclosure
1
25
B Sidewall to Stove Top Plate
6
153
C Front to Combustible
36
914
D Corner to Adjacent Wall
4-3/8
112
E Floor to Ceiling
48
1219
F Top to Combustible Material
19
483
H
J
K
ALCOVE
H Height From Hearth 48” 1219 mm
J Depth
48” 1219 mm
K Width
36” 914 mm
NOTE: Maintain minimum side and
back clearances when placing stove in
alcove.