OVER FIRING OF BURNER
Never “over fire” adjusting gas pressure or drilling
out the orifice to increase Btu/hr above nameplate
specifications. Over firing can cause permanent
damage to firebox and deterioration of parts and
void warranty.
MAINTAINING CORRECT PILOT-FLAME
The pilot flame must be checked during initial
installation and annually by a qualified technician.
This appliance uses flame rectification technology.
If the pilot flame is turned down too low, the flame
sensor may not detect the pilot flame and the pilot
may not stay lit. Do not turn down the pilot flame.
The flame sensor rod may be coated with debris
after a few months of use. It is important to clean
the flame sensor rod using emery cloth if flame
rectification problems are encountered after use
for a few months. Environmental factors beyond
the control of USSC can cause flame rectification
concerns.
HOW TO ACCESS COMPONENTS
The descriptions below show where the main
components are located and how to access them
for service. The descriptions show how to access the
components after the installation. All components
are also accessible from the outside of the appliance
before the it is installed.
Pilot:
The pilot is in the back left corner of the
firebox behind the burner.
Gas Valve: The main gas valve is located in the
bottom cavity of the firebox.
Ignition Control Module:
The ignition control
module is installed in a box with an ON/OFF switch.
It is mounted in the lower cavity to the left of the
gas valve.
Convection Blower:
The convection blower is
mounted on the rear of the unit.
For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: [email protected]
The information in this owner’s manual is specific to your unit. When ordering replacement parts the
information in this manual will help to ensure the correct items are ordered. Before contacting customer
service write down the model number and the serial number of this unit. That information can be found on
the certification label attached to the back of the unit. Other information that may be needed would be the
part number and part description of the item(s) in question. Part numbers and descriptions can be found
in the “Repair Parts” section of this manual. Once this information has been gathered you can contact
customer service by phone 1-800-750-2723 Ext 5051 or Email [email protected].
Model Information
Model Number
Serial Number
HOW TO ORDER REPAIR PARTS
Summary of Contents for AG23
Page 47: ... 2021 United States Stove Company 47 NOTES ...
Page 48: ...48 2021 United States Stove Company NOTES ...
Page 49: ... 2021 United States Stove Company 49 NOTES ...
Page 77: ......