SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  FAIlurE 
TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.

FOr uSE IN ThE u.S. ANd CANAdA.  NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES

IF  ThIS  STOvE  IS  NOT  PrOPErlY  INSTAllEd,  A  hOuSE  FIrE  mAY  rESulT.    FOr  YOur  SAFETY,  FOllOw 
INSTAllATION dIrECTIONS.  

CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION 
rEQuIrEmENTS IN YOur ArEA.

CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE 
PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.

CETTE  guIdE  d'uTIlISATION  EST  dISPONIblE  EN  FrANCAIS.  ChEz  vOTrE  CONCESSIONNAIrE  dE 
hArmAN.

SAvE ThESE INSTruCTIONS.

The harman TlC 2000 Coal/wood Stove

Installation & Operating manual

R9

“Ce manuel est disponible en Français sur demande”

manual # 3-90-08691

Summary of Contents for TLC 2000

Page 1: ...OLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building...

Page 2: ...E THESE INSTRUCTIONS Harman Home Heating 352 Mountain House Road Halifax PA 17032 U S A INDEX Specifications 4 Operation 6 Building a Fire 7 Maintenance 11 Installation 13 Chimney System 15 Parts List...

Page 3: ...ly heavier or lighter than air Therefore it is best to install the detector at table top level rather than on the ceiling like a smoke de tector CO detectors are very sensitive and may sound an alarm...

Page 4: ...ications Harman TLC 2000 Weight 375 lbs Flue Size 6 inch Fuel Pea Nut or Stove coal Cordwood with optionalspark screen Log Length Recommended 16 with 18 Max Heating Capacity 1 900 sq ft Blower Size op...

Page 5: ...Coal Stove Top Load Door Top Load Door Arm Side Shield Ash Door Latch Ash Door Coal Air Control Front Load Door Latch Top Load Opening Glass Door Grates Wood Air Control Removable Shaker Handle Clean...

Page 6: ...the glass is broken or damaged do not operate the stove until it has been replaced Grates The TLC 2000 s unique grate system consists of two Cast iron grates linked together to operate simaltainiousl...

Page 7: ...nded that the coal control be positioned to the left for wood burning WOOD COAL WOOD Building and Maintaining a Wood Fire Neveruse gasoline gasoline type lantern fuel kerosene charcoal lighterfluid or...

Page 8: ...es from the fire chamber periodically by shaking the grates Wood burns best with an ash bed under the wood therefore do not shake all of the ashes down Never let the ashes build up to over 3 in depth...

Page 9: ...mell this is just the paint going through the curing process and will disappear after a few fires Overfiring Avoid overfiring your stove a potentially hazardous situ ation which can lead to overheatin...

Page 10: ...imum postion by sliding it to the right Allow the fire to burn vigorously for several minutes Shake the grates with short choppy strokes until the first red coals fall into the ash pan then stop Add c...

Page 11: ...er or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should be examined for damage to the firebrick lining material and grates If any bricks hav...

Page 12: ...ss while it is hot and do not use abra sive substances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In...

Page 13: ...a grounded outlet and may not be routed above under over or around the stove itself Blower Variable Speed knob Top Air Grill Optional The top air grill must be installed before the chimney con nector...

Page 14: ...ance distances other than those pre sented here Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Page 15: ...your stove Signs of an overdraft include rapid fuel consumption inability to slow the fire and parts of the stove or chimney connector glowing red It is important that you follow the chimney guideline...

Page 16: ...m recommended height for any chimney is 16 ft 4 8 m above flue collar height A round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rec...

Page 17: ...e Be sure to contact your building code inspection official to see if this option is allowed in your area and to find out the specific requirements for such an installation Existing Masonry Chimneys I...

Page 18: ...fuels such as charcoal can cause increased carbon mon oxide production or overfiring Never use highly volatile substances in your stove such as gasoline which could cause an explosion When solid fuel...

Page 19: ...2 00 852132 TLC Bottom Slide Rail 16A 2 00 852135 TLC Airslide 16B 3 31 08739 5 16 18 x 2 1 2 All Thread 17 2 00 852133 TLC Top Slide Tail 18 2 00 854148 TLC Airslide Cover 19 3 40 08746 TLC Airslide...

Page 20: ...TLC 2000 Coal Stove 20 26 28 1 22 21 29 9 14 18 12 13 10B 27 3 2 2 4 5 6 32 31 7 8A 11A 23 17 16A 20 15 19 25 24 30 8B 33 10A 11B 16B...

Page 21: ......

Page 22: ......

Page 23: ...Notes...

Page 24: ...TLC 2000 Owner s Manual 3 90 08691 Rev 9...

Reviews: