5-8
10. Connect the red MaxiClip to the brown/black
wire. The tester must read battery voltage and the
speedometer backlight (5) must illuminate. If the
tester does not read battery voltage, troubleshoot
the ignition switch or wiring harness connectors.
11. Depress and hold the Mode/Set button (1). The
speedometer should switch between mph and
km/h as indicated by icon (12).
12. Depress and hold the Mode/Set button (2). The
distance mode should shift between ODO and
TRIP as indicated by icon (12).
13. Depress and hold the Mode/Set buttons (1) and (2)
simultaneously. The hour segment of the clock
should flash indicating the clock (13) is in the set
mode. Release the Mode/Set button (2) and release
when the desired hour (1-24) appears.
14. Depress and release the Mode/Set button (1) to
shift the clock set to the minute segment; then
depress Mode/Set button (2) to set the desired
minute.
NOTE: In the clock set mode, the gauge will
default to normal operation 10 seconds after the
Mode/Set buttons are released.
15. With the ignition switch in the ON position, use a
small screwdriver or suitable tool to spin the input
quill of the speedometer. The speed indicator (6)
must indicate a value greater than zero.
INSTALLING
To install the LCD gauge assembly, see Section 8 of
this manual.
Ignition Switch
The connector is the white one beneath the front cover.
To access the connector on the 250 Utility, the front
rack and front cover must be removed (see Section 8).
VOLTAGE
NOTE: Perform this test on the lower side of the
connector.
1. Set the meter selector to the DC Voltage position.
2. Connect the red meter lead to the red/white wire;
then connect the black meter lead to ground.
3. The meter must show battery voltage.
NOTE: If the meter shows no battery voltage,
troubleshoot the battery, 30 amp fuse, or the main
wiring harness.
RESISTANCE
NOTE: Perform this test on the upper side of the
connector.
1. Turn the ignition switch to the ON position.
2. Set the meter selector to the OHMS position.
3. Connect the red tester lead to the red wire; then
connect the black tester lead to the black wire.
4. The meter must show less than 1 ohm.
5. Turn the ignition switch to the LIGHTS position.
6. Connect the red tester lead to the red wire; then
connect the black tester lead to the brown wire.
7. The meter must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of
resistance, replace the switch.
Handlebar Control
Switches
Two white connectors join the handlebar control
switch pigtails to the main harness. To access the con-
nectors on the 250 Utility, the front rack and front
cover must be removed (see Section 8).
NOTE: These tests should be made on the switch
side of the connectors with the connectors uncou-
pled.
RESISTANCE (HI Beam)
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the blue wire; then
connect the black tester lead to the brown/black
wire.
3. With the dimmer switch in the HI position, the
meter must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of
resistance, troubleshoot or replace the
switch/component or the connector.
! CAUTION
Always disconnect the battery when performing resis-
tance tests to avoid damaging the multimeter.
! CAUTION
Always disconnect the battery when performing resis-
tance tests to avoid damaging the multimeter.