6RL SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 91 of 204
4.
Activate the lock by leaving the settings page with
.
Note: Be careful to enable the lock if you are unsure what PIN is currently set. In
doubt use ESC to exit the menu page. In menu page “HMI Lock” you can
define a different PIN, but not without entering the old one.
How to Unlock the “Limits” settings:
1.
While the DC Input is switched off, tap the touch area
on the main
screen.
2.
In the menu tap “Limits Lock”.
3.
In the next page set the check mark for “Lock”.
4.
Deactivate the lock by entering the correct PIN and submitting it with ENTER.
6.9
Function Generator Use
6.9.1
FG Introduction
The built-in function generator (short: FG) is able to create various signal forms and apply
these to the set value of voltage or current.
The standard functions are based on an arbitrary generator and directly accessible and
configurable using manual control. For remote control, the fully customizable arbitrary
generator replicates the functions with sequences containing eight parameters each.
Further functions, such as UI-IU, are based on a table with 4096 values, working as XY
function. Battery test and MPP tracking are software based functions only.
The following functions are retrievable, configurable and controllable:
Function
Short description
Sine wave
Sine wave generation with adjustable amplitude, offset and frequency
Triangle
Triangular wave signal generation with adjustable amplitude, offset, rise and fall times
Rectangular
Rectangular wave signal generation with adjustable amplitude, offset and duty cycle
Trapezoid
Trapezoidal wave signal generation with adjustable amplitude, offset, rise time, pulse time,
fall time, idle time
DIN 40839
Simulated automobile engine start curve according to DIN 40839 / EN ISO 7637, split into 5
curve sequences, each with a start voltage, final voltage and time
Arbitrary
Generation of a process with up to 99 freely configurable curve points, each with a start and
end value (AC/DC), start and end frequency, phase angle and total duration
Ramp
Generation of a linear rise or fall ramp with start and end values and time before and after the
ramp
UI, IU
Table (.csv) with values for U or I, uploaded from an USB stick, as well as
Battery test
Battery discharge test with constant or pulsed current, along with Ah, Wh and time counters
MPP Tracking
Simulation of the characteristic tracking behavior of solar inverters when seeking to find the
maximum power point (MPP) when being connected to typical sources such as solar panels
Table 6-5: Function Generator Capacities Overview