6RL SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 50 of 204
Figure 5-4: DC Terminal Types 1 & 2
5.10.3
Output Cable Safety Covers
A plastic safety cover for contact protection is included for the DC terminals. This cover
should always be installed. The cover for type 2 (see picture above) is fixed to the connector
itself. The cover for type 1 attaches to the rear panel of the unit. The cover for type 1 has
several breakouts so that the supply cable exit the cover in different directions.
The connection angle and the required bending radius for the DC cable must be taken into
account when planning the depth of the complete unit + cabling, especially when installing
in a 19” cabinet or similar. For type 2 connectors only a horizontal direction lead can be used
to allow for installation of the safety cover.
Examples of Type 1 terminal connections:
90° up or down
Depth space savings
No bending radius
Horizontal break-out
Height space savings
Bending radius required