15 kW
Model
6RL15-60-750-4
6RL15-40-1000-4
6RL15-30-1500-4
Analog interface
(3
Set value inputs
U, I, P, R
Actual value output
U, I
Control signals
DC input on/off, remote control on/off, R mode on/off
Status signals
CV, OVP, OT
Galvanic isolation to the device
max. 1500 V DC
Sample rate (set value inputs)
500 Hz
Insulation
Allowed potential shift (floating voltage) on the DC input:
Input (DC) to enclosure
±1500 V DC
±1500 V DC
±1500 V DC
Input (AC) to input (DC)
±1800 V DC
±1800 V DC
±1800 V DC
Environment
Cooling
Temperature controlled fans
Ambient temperature
0..50 °C (32...122°F)
Storage temperature
-20...70 °C (-4...158°F)
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and logging, 1x Master-slave bus,
1x GPIB (optional)
Interface modules slot
(2
optional: CANopen, Profibus, Profinet, RS232, CAN, Ethernet, ModBus TCP, EtherCAT
Galvanic isolation to the device
max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B,
master-slave bus, Interface module slot
Front side
USB-A
Dimensions
Enclosure (WxHxD)
19“ x 3U x 669 mm (26.3”)
Total (WxHxD)
483 mm x 133 mm x 775 mm (19” x 5.2” x 30.5”)
Standards
EN 61010-1:2011-07, EN 50160:2011-02 (grid class 2), EN 61000-6-2:2016-05, EN
61000-6-3:2011-09 (radiation class B)
Weight
~32 kg (70.5 lbs)
~32 kg (70.5 lbs)
~32 kg (70.5 lbs)
1.
For technical specifications of the analog interface see section 6.5.3.4, “Analog Interface Specifications” on page
82.
2.
Only in the standard version