6RL SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 29 of 204
5 kW
MODEL
6RL05-170-80-4 6RL05-70-200-4 6RL05-40-360-4 6RL05-30-500-4 6RL05-20-750-4
Model
6RL05-170-80-4
6RL05-70-200-4
6RL05-40-360-4
6RL05-30-500-4
6RL05-20-750-4
Set value inputs
U, I, P, R
Actual value output
U, I
Control signals
DC input on/off, remote control on/off, R mode on/off
Status signals
CV, OVP, OT
Galvanic isolation to the device
max. 1500 V DC
Sample rate (set value inputs)
500 Hz
Insulation
Allowed potential shift (floating voltage) on the DC input:
Input (DC) to enclosure
±400 V DC
±725 V DC
±725 V DC
±1500 V DC
±1500 V DC
Input (AC) to input (DC)
±400 V DC
±1000 V DC
±1000 V DC
±1800 V DC
±1800 V DC
Environment
Cooling
Temperature controlled fans
Ambient temperature
0..50 °C (32...122°F)
Storage temperature
-20...70 °C (-4...158°F)
Digital interfaces
Featured
1x USB-B for communication, 1x USB-A for functions and logging, 1x Master-slave bus,
1x GPIB (optional)
Interface modules slot
(2
optional: CANopen, Profibus, Profinet, RS232, CAN, Ethernet, ModBus TCP, EtherCAT
Galvanic isolation to the device
max. 1500 V DC
Terminals
Rear side
Share Bus, DC input, AC input/output, remote sensing, analog interface, USB-B, master-
slave bus, Interface module slot
Front side
USB-A
Dimensions
Enclosure (WxHxD)
19“ x 3U x 668 mm (26.3”)
Total (WxHxD)
483 mm x 133 mm x 775 mm (19” x 5.2” x 30.5”)
Standards
EN 61010-1:2011-07, EN 50160:2011-02 (grid class 2), EN 61000-6-2:2016-05, EN 61000-
6-3:2011-09 (radiation class B)
Weight
~18 kg (39.7 lb)
~18 kg (39.7 lb)
~18 kg (39.7 lb)
~18 kg (39.7 lb)
~18 kg (39.7 lb)
1.
For technical specifications of the analog interface see section 6.5.3.4, “Analog Interface Specifications” on
page 82.
2.
Only in the standard version
Summary of Contents for 6RL Series
Page 203: ......