Simple changes in firmware can have crucial effects on the application the units are
used in. We thus recommend to study the list of firmware changes in the revision
history very thoroughly.
Newly implemented features may require an updated documentation (user manual
and/or programming guide, as well as LabView™ drivers), which are often available
later, in some cases significantly later.
5.16
Cleaning
This unit needs no maintenance. Cleaning of the internal fans may be needed. The
frequency of cleaning depends on the ambient conditions. The fans serve to cool the
components, which are heated by normal internal power losses. Heavily dirt clogged fans
can lead to insufficient airflow and therefore the DC Input can switch off prematurely due to
overheating. Defects can possibly result in this case.
Cleaning the internal fans can be performed with a vacuum cleaner or similar. To do so, the
units needs to be opened
To clean the exterior of this unit uses a soft or slightly damp cloth.
CAUTION
BEFORE you clean the unit, switch the mains power off and disconnect the
input line cord.
・
Please do NOT use any organic solvent capable of changing the nature of
the plastic such as benzene or acetone.
・
Please ensure that no liquid is allowed to penetrate this product.
5.17
In Case of Malfunction
In the unlikely event of an instrument malfunction or if the instrument does not turn on
despite the presence of the correct AC line voltage, please attach a warning tag to the
instrument to identify the owner and indicate that service or repair is required. Contact
Adaptive Power Systems or its authorized representative to arrange for service.