6RL SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 79 of 204
6.4.10.4
Log file format
Type: text file in European or US American CSV format (depending on the selected setting)
Layout (US format shown):
Legend:
U set / I set / P set / R set: Set values
U actual / I actual / P actual / R actual: Actual values
Error: unit alarms
Time: elapsed time since logging start
Unit mode: actual regulation mode (also see section 3.4, “Operating Modes”).
Note: R set and R actual are only recorded if UIR mode is active (refer to section 3.4.5)
Note: Unlike the logging on PC, every log started creates a new log file with a sequence
counter in the file name, normally starting with 1, depending on existing files.
6.4.10.5
Special notes and limitations
Following provisions apply to data logging:
Max. log file size (due to FAT32 formatting): 4 GB
Max. number of log files in folder HMI_FILES: 1024
With setting “Start/stop with DC Input ON/OFF”, the logging will also stop on alarms
or events with action “Alarm”, because they switch off the DC Input
With setting “Manual start/stop” the unit will continue to log even on occurring
alarms, so this mode can be used to determine the period of temporary alarms like
OT or PF