6RL SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 63 of 204
MENU
General Settings
Page 1
Allow remote control: YES | NO
Analog Interface range: 0..5V | 0..10V
User Events
Profiles
Default
Profile
Page 2
Analog Interface Rem-SB: Normal | Inverted
Analog Rem-SB action: DC OFF | DC ON/OFF
Overview
User Profile 1
Page 3
Analog Interface pin 6: Alarm OT • Alarm PF
•
About HW, SW…
User Profile 2
Analog Interface pin 15: Alarm OVP • OCP •
OPP •
Page 4
Analog Interface pin 15: Regulation Mode •
DC Status •
User Profile 3
Page 5
DC Input after power ON: OFF | Restore
User Profile 4
Page 6
DC input after PF alarm: OFF | AUTO
User Profile 5
DC input after remote: OFF | AUTO
Page 7
Enable R mode: YES | No
Page 8
USB decimal point format: US | Default
USB logging with units (V,A,W): Yes | No
Page 9
Calibrate Device: Start
Page 10
Reset device to defaults: Start
Restart device: Restart
Page 11
Master-Slave mode: OFF | MASTER | SLAVE
Page 12
Repeat master init.: Initialize
Event U
UVD = {0V...Unom}
Action = {NO | SIGNAL | WARNING |ALARM}
OVD = {0V...Unom}
Action = {NO | SIGNAL | WARNING |ALARM}
Event I
UCD = {0A...Inom}
Action = {NO | SIGNAL | WARNING |ALARM}
OCD = {0A...Inom}
Action = {NO | SIGNAL | WARNING |ALARM}
Event P
OPD = {0W...Pnom}
Action = {NO | SIGNAL | WARNING |ALARM}
Note:
Parameters in curly brackets describe the selectable range, underlined parameters show the default
value after delivery or reset
.