125
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-34 (JC)
Jog mode speed 6
Data Range
Default
Unit
LED Display
0.025 - 100
35
rps
8400
The sixth speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-35 (JC)
Jog mode speed 7
Data Range
Default
Unit
LED Display
0.025 - 100
40
rps
9600
The seventh speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-36 (JC)
Jog mode speed 8
Data Range
Default
Unit
LED Display
0.025 - 100
50
rps
12000
The eighth speed used in velocity mode. This only applies to control modes 13, 14, 17, and 18.
P-37 (ER)
Encoder resolution
Data Range
Default
Unit
LED Display
200 - 12800
2500
lines
1250
Sets the encoder resolution in quadrature counts. For example, if the motor connected to the drive has an 10000 count (2500 line) per
revolution encoder, set the encoder resolution to 2500.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
V x 6
Where
V
number of Encoder lines
NOTE: when using a Applied Motion Products’ motor please DO NOT change this parameter
P-39 (EG)
Electronic gearing
Data Range
Default
Unit
LED Display
200 - 32000
10000
counts
5000
EG defines the pulses per revolution for electronic gearing. For example, with an EG value of 10000 the servo drive will require 10000
pulses from the master pulse source to move the servo motor 1 revolution.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
EG / 2
Where
EG
is electronic gearing ratios, units counts.
P-40 (PV)
Secondary Electronic gearing
Data Range
Default
Unit
LED Display
200 - 32000
10000
counts
10000
PV defines the pulses per revolution for secondary electronic gearing. Refer to Section 7.2.3 Control Pulse Dividing Switch Function.
P-41 (EN)
Numerator of electronic gearing
ratio
Data Range
Default
Unit
LED Display
1 - 1000
1000
1000(Note)
Defines the numerator of electronic gearing ratio. Refer to Section 7.2.5 Electronic Gearing Ratio.
NOTE:
1.
For firmware 1.00K or lower, if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
V x 32
Where
V
is electronic gearing ratios, units counts.
2.
For Firmware 1.00L or above, no calculation is needed