86
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.2.8 Gain Parameters For Position Control Mode
In position mode, proper gain parameters will cause the servo system to run and stop more smoothly, and accurately, thereby
optimizing its performance.
In most cases, SVX Servo Suite’s auto tuning function will help to automatically tune these parameters. However, in some cases, the
fine tuning function from the software or parameter setting mode on the drive may be needed to optimize performance.
Parameter
Name
Data Range
Default
LED Display
P-00(KP)
Global gain 1
0~32767
8000
8000
P-01(KG)
Global gain 2
0~32767
12000
12000
P-02(KF)
Proportional Gain
0~32767
10000
10000
P-03(KD)
Derivational Gain
0~32767
2000
2000
P-04(KV)
Damping Gain
0~32767
8000
8000
P-05(KI)
Integrator gain
0~32767
500
500
P-06(KK)
Inertia Feedforward Constant
0~32767
800
800
P-07(KJ)
Jerk Filter Frequency
0~32767
5000
5000
P-10(KE)
Deriv Filter factor
0~32767
15000
15000
P-11(KC)
PID Filter factor
0~32767
20000
20000