24
SV200 DC Hardware Manual
920-0126A
4/14/2017
3 Installation
3.1 Storage Conditions
• Store properly packaged in a clean and dry environment,away from direct sunlight
• Store in an ambient temperature range of -10°C to +85°C
• Store where the relative humidity range is 10% to 85% with non-condensing
• DO NOT store in a place exposed to corrosive gases
3.2 Installation Conditions
• Temperature range of 0°C to 50°C. If the ambient temperature of the servo drive is greater than 40°C, please install it in a
well-ventilated location.
• The ambient temperature of the servo drive for long-term reliability should be less than 45°C.
• The servo drive and motor will generate heat; if they are installed in a control panel, please
ensure sufficient space around the units for heat dissipation.
• Operate where the relative humidity range is 10% to 85% and non-condensing
• Install where the vibration is lower than 5.88m/s
2
, 10Hz-60Hz (DO NOT use the drive for extended periods of time at the
resonance point.)
• DO NOT install the servo drive and motor in a location subjected to corrosive or flammable gases, or combustibles.
• Install the servo drive and motor in an indoor electric control cabinet.
• DO NOT install the servo drive and motor in a location subject to airborne dust.