173
SV200 DC Hardware Manual
920-0126A
4/14/2017
Setup Software Position Limits
Here are the basic steps to set the soft limits, also shown below:
A.
Before rotating the motor and setting limits, first set the desired Jog Speed, and Accel/Decel rate.
B.
Set CCW limit – move to desired position with arrow buttons, then click the flag button
C.
Set CW limit – move to desired position with arrow buttons, then click the flag button
D.
Confirm or Cancel position limits set in step B and C with the Set Limit or Clear Limit buttons
Detailed Steps for Software Position Limit
Step
Operation
Software
1
Make sure Servo is Enabled
Click
or
to rotate motor in CCW or CW direction
When target position reached, click
to accept and store
position
2
Same process as above
3
Confirm position limits
Click on
NOTE: CW limit must be larger than CCW
limit.
4
Setting complete