172
SV200 DC Hardware Manual
920-0126A
4/14/2017
In the pop-up menu, click on the drop-down motor list to choose the correct motor number and then click “
OK
”.
NOTE: Refer to the SV200 Series AC Servo User Manual, Chapter 2.3 Servo Motor Model
Introduction for motor identification details.
11.2.2 Step 2: Setting the Software Position Limits
The Software Position Limit function uses encoder counts to set “soft” limits at user-defined locations that can then be used during
the tuning process. These position limits ensure that the motor will ONLY rotate between the CCW and CW limits, which will help to
prevent accidental system damage. This is especially useful when the motor is coupled to a linear actuator, for instance.
NOTE: The software Position Limits will ONLY be effective during current power-up operation and will not be saved to non-volatile
memory for use at the next drive power up. Therefore, DO NOT rely on these software limits during actual system operation. Refer to
LP and LM commands in SVX SVX Servo Suite’s built-in Q Programmer help for more details.
On the “
Tuning- Sampling
” panel, select the “
Limit
” tab to setup software position limits. If software position limits are not
required, then click “
Clear Limit
” and go to the next step for the “
Auto-Tune
” function description.