P-16 (GC)
Current Command of Torque Mode
Data Range
Default
Unit
LED Display
Based on drive’s output
ability
0
0.01A
0
The immediate current for the servo motor and drive when the servo drive is set for Command Torque Mode.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 100
Where is target setting current, Unit for is A (amps)
P-17 (CC)
Rated Maximum current
Data Range
Default
Unit
LED Display
Depends on motor model
0.5
A
50
The continuous (RMS) current setting of the servo drive.
NOTE: In normal operation, please DO NOT change this parameter.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 100
Where is target setting current, Unit for is A (amps)
P-18 (CP)
Peak current
Data Range
Default
Unit
LED Display
Depends on motor model
1.5
A
150
CP sets the peak (RMS) current setting of the servo drive. Peak current sets the maximum current that should be used with a given
motor. When the motor position requires more than the continuous value, the peak current time calculation is done using i
2
t which
integrates current values for more accurate modeling of drive and motor heating. The servo drive will allow peak current for up to one
second. After one second of operation at peak current the current is reduced to the continuous current setting (see CC command).
NOTE: In normal operation, please DO NOT change this parameter.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 100
Where is target setting current, Unit for is A (amps)
P-20 (VM)
Maximum velocity
Data Range
Default
Unit
LED Display
0.025 - 100
110
rps
26400
The maximum motor velocity in rev/sec. Used in all control modes to limit the maximum speed of the drive.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
x 240
Where is target velocity setting, Unit is rps (rev/sec).
P-21 (AM)
maximum acceleration/
deceleration
Data Range
Default
Unit
LED Display
0.167 - 5000
3000
rps/s
18000
The maximum acceleration/deceleration allowed. When the targeted acceleration/deceleration exceeds the maximum value, the actual
acceleration/deceleration will be limited to the maximum value.
Also sets the deceleration rate used when an end-of-travel limit is activated during a move or when an ST (Stop) or SK (Stop & Kill)
command is sent.
NOTE: if you need to view or set this value on the drive’s control panel, refer to the following calculation: